12 Instruction manual “1353-EN”
Heat pump, split, single service
Line
Function Settingrangeor
display
Setting
increment
B a s i c
setting
Heatingtimeprogramme,circuit2
Iftheinstallationconsistsof2heatingcircuits(onlywiththe2ndcircuitkitoption)
520 Pre-selection(day/week)
Mon-SunMon-FriSat-SunMondayTuesday…
Mon-Sun
521 1stphaseOn(start) 00:00…--:-- 10min 6:00
522 1stphaseOff(end) 00:00…--:-- 10min 22:00
523 2ndphaseOn(start) 00:00…--:-- 10min --:--
524 2ndphaseOff(end) 00:00…--:-- 10min --:--
525 3rdphaseOn(start) 00:00…--:-- 10min --:--
526 3rdphaseOff(end) 00:00…--:-- 10mn --:--
536 Standardvalues,Circuit2 no,yes no
Yes + OK: The standard values memorised in the regulator replace and cancel the customised heating programmes. Your
customised settings are therefore lost.
Timeprogramme4/ DHW
Iftheinstallationisfittedwithatank(onlywiththeDWHkitoption)
560 Pre-selection(day/week)
Mon-SunMon-FriSat-SunMondayTuesday…
Mon-Sun
561 1stphaseOn(start) 00:00…--:-- 10min 00:00
562 1stphaseOff(end) 00:00…--:-- 10min 05:00
563 2ndphaseOn(start) 00:00…--:-- 10min --:--
564 2ndphaseOff(end) 00:00…--:-- 10min --:--
565 3rdphaseOn(start) 00:00…--:-- 10min --:--
566 3rdphaseOff(end) 00:00…--:-- 10min --:--
576 Standardvalues no,yes no
Yes + OK: The standard values memorised in the regulator replace and cancel the customised heating programmes. Your
customised settings are therefore lost.
Timeprogramme5/Cooling
Iftheinstallationisfittedwiththecoolingkit(onlywiththecoolingkitoption)
600 Pre-selection(day/week)
Mon-SunMon-FriSat-SunMondayTuesday…
Mon-Sun
601 1stphaseOn(start) 00:00…--:-- 10min 6:00
602 1stphaseOff(end) 00:00…--:-- 10min 22:00
603 2ndphaseOn(start) 00:00…--:-- 10min --:--
604 2ndphaseOff(end) 00:00…--:-- 10min --:--
605 3rdphaseOn(start) 00:00…--:-- 10min --:--
606 3rdphaseOff(end) 00:00…--:-- 10min --:--
616 Standardvalues no,yes no
Yes + OK: The standard values memorised in the regulator replace and cancel the customised heating programmes. Your
customised settings are therefore lost.