30 Operating Manual
RX2520 M1
Noise level (depending on the configuration)
The acoustic noise values are depending on the system configuration.
Electrical data (AC hot-plug power supply unit)
Minimum configuration Standard configuration
Sound power level
L
WAd
(ISO 9296)
< 5.1 B (standby)
< 5.1 B (operation)
< 8 B (full fan speed)
< 5.2 B (standby)
< 5.3 B (operation)
< 8.2 B (full fan speed)
Sound pressure
level at adjacent
workstation
L
pAm
(ISO 9296)
< 34 dB(A) (standby)
< 34 dB(A) (operation)
< 63 db(A) (full fan speed)
< 36 db(A) (standby)
< 36 db(A) (operation)
< 65 db(A) (full fan speed)
Rated voltage range 100 V - 240 V
Frequency 50 Hz - 60 Hz
Max. rated current 3.4 A - 6.9 A / 100 V - 240 V
Effective power 450/800 W
Apparent power 690 VA - 816 VA / 100 V - 240 V
Heat dissipation 2938 kJ/h (2784 Btu/h)
Main power fuse 16 A
Protection class I