Operating Manual 67
Starting up and operation
Power-off indicator (AC connected) (green)
above the On/Off button
Does not light up in the following cases:
the system is not connected to the mains
the system is powered on and in normal operation (S0)
Lights up green in the following cases:
the system is in power-off mode but connected to the mains (AC
connected)
the system has been switched on and is in power-on delay
I After connecting the server to the mains it takes about 60
seconds until the server enters the standby mode.
HDD/SSD activity indicator (green)
Lights up green when an internal drive (HDD or backup drive) is
being accessed.
Global Error indicator (orange)
Lights up orange if a prefailure event has been detected that
requires (precautionary) service intervention.
Flashes orange if an error was detected that requires service
intervention.
Does not light up if there is no critical event.
If the event is still acute after a power cycle, the indicator is activated
after the restart.
The indicator also lights up in standby mode.
You can find more details on the indicated errors in the System
Event Log (SEL), on the ServerView Local Service Panel, in the
ServerView Operations Manager or via the iRMC S4's Web
interface.
!