RX300 S7 Operating Manual 31
Functional overview
Electrical data (AC hot-plug power supply unit)
Electrical data (optional DC hot-plug power supply unit)
Rated voltage range 100 V - 240 V
Frequency 50 Hz - 60 Hz
Max. rated current 8.2 A - 3.3 A / 100 V - 240 V
Effective power 450/800 W
Apparent power 873 VA - 829 VA / 100 V - 240 V
Heat dissipation 2638.8 kJ/h (2501.7 btu/h)
Main power fuse 16 A
Protection class I
Rated voltage range -40.5 V ... -57 V
Frequency DC
Max. rated current 23.8 A - 16.4 A / 40.5 V - 57 V
Effective power 800 W
Main power fuse 16 A