TX1310 M3 Operating Manual 41
Hardware installation
5.2 Setting up the server
Ê Transport the server to the place where you want to set it up.
Ê Unpack the server (see section "Unpacking the server" on page 40).
Ê Set up the server.
V CAUTION!
The device must be protected from direct sunlight.
The required minimum distances for operation and maintenance
areas must be adhered to.
The server must be accessible at the rear for connection to other
devices (e.g. memory subsystem).
The mains plug must be accessible easily and safely.
There must be a clearance of at least 200 mm in front of and
behind the server to ensure adequate ventilation of the
subsystem.
Ê Wire the server. Follow the instructions in sections "Connecting devices to
the server" on page 42 and "Notes on connecting/disconnecting cables" on
page 44.
Ê Connect the server to the mains (see section "Connecting the server to the
mains" on page 44).