26 Operating Manual TX2550 M4
Functional overview
Dimensions / weight
Ventilation clearance
There must be a clearance of at least 200 mm in front of and behind the server
to ensure adequate ventilation of the subsystem.
Ambient conditions
Condensation during operation must be avoided!
Floorstand (W x D x H) 177 mm x 777 mm x 456 mm
Rack (W x D x H) 482.6 mm (bezel) / 448 mm (body) x 736 mm x
177 mm
Height unit rack 4 U
Mounting depth rack 700 mm
19" rack mount Yes
Weight 35 kg
Weight notes Weight may vary depending on actual configuration
Rack mounting kit Rack mounting kit as option
Environment class 3K2
Environment class 2K2
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2) 5°C ... 40°C (with Fujitsu ATD 40°)
5°C ... 45°C (with Fujitsu ATD 45°)
10°C ... 35°C (without Fujitsu ATD)
Transport (2K2) -25°C ... 60°C
Humidity 10% ... 85% (non condensing)