TX2550 M4 Operating Manual 49
5.2 Setting up the floorstand model
I If you are not installing a PRIMERGY TX2550 M4 floorstand model, skip
this section and continue reading at section "Installing/removing the
server in/from the rack" on page 50.
V CAUTION!
Please note the safety instructions in chapter "Important information" on
page 33.
Ê Transport the server to the place where you want to set it up.
Ê Unpack the server (see section "Unpacking the server" on page 48).
Ê Set up the server.
V CAUTION!
– The device must be protected from direct sunlight.
– The required minimum distances for operation and maintenance
areas must be adhered to.
– The server must be accessible at the rear for connection to other
devices (e.g. memory subsystem).
– The mains plug must be accessible easily and safely.
– There must be a clearance of at least 200 mm in front of and
behind the server to ensure adequate ventilation of the
subsystem.
Ê Wire the server. Read the information in section "Connecting devices to the
server" on page 51 and section "Notes on connecting/disconnecting cables"
on page 57.
Ê Connect the system to the mains (see section"Connecting the server to the
mains" on page 55).