86 Operating Manual TX2550 M4
Troubleshooting and tips
8.7 Incorrect date and time
Ê Set the date and time in the operating system or in the BIOS Setup under
the Main menu, using System Date and System Time respectively.
I Note that the operating system may affect the system time. For example,
the operating system time may deviate from the system time under
Linux, and would overwrite the system time in the default setting on
shutdown.
If the date and time are still wrong after the server has been switched off and
back on again, replace the lithium battery (for a description refer to the
"FUJITSU Server PRIMERGY TX2550 M4 Upgrade and Maintenance Manual")
or contact our customer service team.
8.8 System will not boot
The system will not boot after installing a new hard disk drive.
SAS configuration incorrect
Ê Check the settings for the hard disk drives (SAS Device Configuration) and
the additional settings in the SAS configuration menu.
8.9 HDD error messages at system boot
Various HDD error messages may occur when the system is rebooted. These
error messages are caused by modifications in the selected RAID configuration.
RAID controller configuration incorrect
Ê Check and correct the settings for the drives using the RAID controller
configuration program.
For more information, see the documentation for the RAID controller.

Table of Contents

Other manuals for Fujitsu PRIMERGY TX2550 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX2550 M4 and is the answer not in the manual?

Fujitsu PRIMERGY TX2550 M4 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX2550 M4
CategoryServer
LanguageEnglish

Related product manuals