3-3-3 IndividualHold
“Individual Hold” can be used only with cassette type indoor
unitwhichsupportsthisfunction.Theairowdirectioncan
be set for each outlet of single or multiple indoor units con-
nected to this remote controller.
(1) Touch the [Individual Hold] on
the “Air Flow Direction Setting”
screen.
1
Air Flow Direction Setting
Back
Individual Hold
VT
Setting
Swing
HZ
Setting
(2) Touch the unit number you
want to set on the “Individual
Hold” screen.
01-01
01-05
01-02
01-06
01-03
01-07
01-04
01-08
Individual Hold
Page 1/ 2
Back
Reset
Next
Page
Unit 1
Unit 5
Unit 2
Unit 6
Unit 3
Unit 7
Unit 4
Unit 8
* [Comfort] is set to the shaded indoor unit as shown (2a)
below. When it is touched, the message is displayed
as shown (2b) below.
(2a) (2b)
01-01
01-05
01-02
01-06
01-03
01-07
01-04
01-08
Individual Hold
Page 1/ 2
Back
Reset
Next
Page
Unit 1
Unit 5
Unit 2
Unit 6
Unit 3
Unit 7
Unit 4
Unit 8
Close
Individual Hold
Air flow direction setting cannot be performed.
Set the Comfort to "Disable".
* When multiple indoor units are connected to this
remote controller,the indoor unit selection screen is
displayed. When the screen (2) has 2 pages, they can
be switched by touching the [Next Page] or [Previous
Page]. When this remote controller is connected to
multiple indoor units, the address (XX-XX) is displayed
for each indoor unit. Touch the indoor unit to be set. [
✓
]
is displayed at the set indoor units.
NOTES
• Tocleartheairowdirectionsettingofallthe
displayed indoor units, touch [Reset]. When [Yes]
oftheconrmationscreenistouched,thesettingis
clearedandswitchestotheairowdirectionsetting
of “VT setting” (Refer to 3-3-1).
• When you want to change the order of the indoor
units displayed on the indoor unit selection screen,
consult your installer or service personnel.
(3) Theoutletportselectionscreenthatsetstheairow
direction is displayed. Touch the outlet port to be set.
• Cassettetype
Check the position of each outlet port based on “
”
mark of the indoor unit body.
Position of the mark
Indoor Unit 1
(
00-00
)
Back Reset
Outlet
utlet 2
Outlet
utlet 4
NOTE
• To clear all outlet port settings of selected indoor
units,touch[Reset].When[Yes]oftheconrma-
tion screen is touched, the setting is cleared and
switchestotheairowdirectionsettingof“VTset-
ting” (Refer to 3-3-1).
• 3Dowcassettetype
Thenumberofoutletportdiersdependingonthemodel
.
Indoor Unit 1
(
00-00
)
Left RightCenter 2Center 1
Back Reset
Indoor Unit 1
(
00-00
)
Left RightCenter
Back Reset
(4) Theairowdirectionsettingscreenisdisplayed.Touch
[VT] or [HZ].
Whentheindoorunitdoesnothaveaowdirection
adjustment function(vertical/horizontal),[VT Setting]/[HZ
Setting]isnotdisplayedandtheairowdirectioncannot
be set.
• VT Setting
“VT Air Flow Direction Setting” screen is displayed.
Touch
[ ]
or
[ ]
andsettheairowdirectionor
“Swing”.
Indoor Unit 1
(
00-00
)
1
VT
1
HZ
Back
1
Indoor Unit 1
(
00-00
)
Cance
K
Outlet 1
• HZ Setting
“HZ Air Flow Direction Setting” screen is displayed.
Touch [
] or [ ]andsettheairowdirectionor
“Swing”.
Indoor Unit 1
(
00-00
)
VT
1
HZ
Back
1
1
Indoor Unit 1
(
00-00
)
Cancel OK
Center
HZ
Setting
NOTE
• Whentheairowdirectionsettingof“VTsetting”(Refer
to 3-3-1) or “HZ setting”(Refer to 3-3-2) is set at the
outlet port, “—” is displayed at the outlet port screen.
3-4 Timer Setting
(1) Touch the [Timer Setting] on the “Main Menu” screen.
(2) “Timer Setting” screen is displayed.
(1) (2)
Monitor
Next
Page
Page 1/ 3
Main Menu
Air Flow Direction
Setting
Weekly Timer
Setting
Timer Setting
Comfort
Back
On Time
Disable]
[Disable]
[Disable]
Off Timer
Auto Off Timer
Timer Setting
Thefollowingtimersettingsarepossible:
• OnTimer:
The stopped indoor unit starts to operate after the set
time.
• OTimer:
The operating indoor unit stops to operate after the set
time.
• AutoOTimer:
WhenindoorunitoperationisstartedbytheOn/O
button of this unit, operation stops after the set time.
When the item to be set is touched, the display switches
to each setting screen. When each setting is complete
or canceled, the display returns to this screen. When
[Back] is touched, the display returns to the “Main
Menu” screen.
En-9