• Economy:
ON or OFF of the economy setting is displayed.
• AntiFreeze*:
ON or OFF of the anti freeze setting is displayed.
< Page 2 >
• Under Maintenance
• Forced Stop
• Mode Mismatch
Previous
Page
Status
R.C. Prohibition
Special State
Page 2/ 4
Monitor
Next
Page
• R.C.Prohibition:
The functions whose operation from this unit and Wireless
type remote controller is prohibited by the Central Control-
ler are displayed by icons. The contents of each icon are
asfollows:
:Alloperations :OnandO
:On :Modesetting
:Temperaturesetting :Timersetting
:Filtersignreset
When you try to operate or set the
prohibited function, the following
screen is displayed and operation
or setting is not possible. When
the [Close] is touched, the display
returns to the screen before opera-
tion was performed.
Setting is prohibited.
Close
< Page 2 (to 3 or 4) >
• Op. Controlled
• Set Temp. Limited
• Energy Saving Operation
• Defrost
• Oil Recovery
Status
Special State
Page 3/ 4
Monitor
Previous
Page
Next
Page
• Human Sensor Setting
• Fan Control for Energy Saving
Status
Special State
Page 4/ 4
Monitor
Previous
Page
• Special State (Page 2, 3 or 4)
The indoor unit status is displayed. When the contents to
be displayed exceeds 3, they are displayed on the next
page(Page3or4).Thestatuscontentsareasfollows:
(Only items that indoor unit supports or operating items
are displayed.)
UnderMaintenance:
Indoor unit is inspected. Indoor unit operation is stopped
during this time.
ForcedStop:
Indoor unit is stopped forcibly by external input.
ModeMismatch:
A mode which cannot be operated simultaneously with a
master indoor unit or other operating indoor unit is set in
the same RB group of a heat recovery system or in the
same refrigerant system of a heat pump system. In this
case, since the mode is switched to the fan mode, reset
to a mode that can be operated simultaneously. Refer to
[4OPERATIONTIPS]→[4.1SelectableModes]forthe
modes which can be operated simultaneously.
OperationControlled:
This content is displayed at the Slave indoor unit when Master
indoor unit is set in the refrigerant system or RB Group to
which this unit is connected. When a Master indoor unit is
not set, this shows that there is already another indoor unit
operating. Only a mode set by Master indoor unit or a mode
that can be operated simultaneously with another operating
indoor unit can be selected. Refer to [4.OPERATION TIPS]
for the modes which can be operated simultaneously.
SetTemp.Limited:
Indoor unit temperature setting is limited by the Central
controller.
EnergySavingOperation:
The energy saving is set by the Energy Manager for Sys-
tem Controller.
Defrost:
At heating operation, the outdoor unit performs Defrost
operation. The indoor unit fan is stopped during this time.
OilRecovery:
The outdoor unit performs oil recovery operation. The
indoor unit fan may be stopped during this time.
HumanSensorSetting:
Thisfunctionisenabled.Referto[3SETTING]→[3-6Spe-
cialSetting]→[3-6-5HumanSensorSetting].
FanControlforEnergySaving:
Thisfunctionisenabled.Referto[3SETTING]→[3-6Spe-
cialSetting]→[3-6-6FanControlforEnergySaving].
< Error Information screen >
[Error Information] is displayed only when there is an error
history. When the [Error Information] is touched, the display
switches to “Error Information” screen. Refer to [5-3 ERROR
CODE] for the errors.
Air Flow Direction
VT
On On
Comfor
omfort
On
HZ
Comfort Economy
Individual Individual
Anti Freeze
Monitor
Next
Page
Error
Information
Status
Page 1/ 4
02-01
14,15, 41, 44
Error Information
Page 1/ 5
Address
Error Code
Back
Next
Page
1-1-3 Child Lock
When this screen is displayed by
touching the monitor mode screen,
the unit is in child safety lock.
Child Lock ValidChild Lock Valid
• Childsafetylockset/reset:
PresstheOn/Obuttonfor4secondsormorewhile
touching an area outside the operation section of the moni-
tor mode screen (no response even if touched). Set/reset
can be performed even while the indoor unit is stopped.
The setting cannot be performed at screens other than the
monitor mode screen.
26.0
°C
Cool
Auto
Set Temp.
Mode
MenuStatus
Fan
Fri 10:00AM
1-1-4 EmergencyStop
This screen is displayed when the
system was emergency stopped by
operation from the outside. When
emergency stop is reset, the moni-
tor mode screen is displayed.
Emergency Stop
En-6