EasyManua.ls Logo

Fujitsu Waterstage Split Comfort 5 Series - Page 13

Fujitsu Waterstage Split Comfort 5 Series
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 13 -
g. 9 - Hydraulic unit components
Key :
1. Electric control box.
2. Controller / User interface.
3. ON/OFF Switch.
4. Hydraulic unit circulation pump.
5. Distribution valve.
6. "Gas" refrigeration connection.
7. "Liquid" refrigeration connection.
8. Condensation sensor.
9. Drain valve.
10. Safety valve.
11. Safety thermostat.
12. Pressure gauge.
13. Automatic bleeder valve.
14. Expansion vessel.
15. Condenser.
16. Heat Pump electrical backup.
17. Domestic Hot Water electrical backup.
Sensors :
20. Heat Pump return sensor.
21. Domestic Hot Water sensor.
22. Heat Pump ow sensor.
Hydraulic unit
12
3
1
10
4
9
8
14
22
13
5
17
21
16
11
9
2
15
13
67
20
Waterstage Split Comfort DHW Serie / INSTALLATION / 2125 - EN

Table of Contents