- 82 -
Settings sheet
Setting Description Set to. Menus
Preliminary settings
20 language operator
section
1 hour / minutes time & date
2 day / month time & date
3 year time & date
5700 installation con g. con guration
Heating circuit No. 1
if 2 circuits = the least warm one (e.g.: oor)
710 comfort setpoint HC1 adjust.
712 reduced setpoint HC1 adjust.
720 heating curve slope HC1 adjust.
741 ow temp setpoint max HC1 adjust.
750 room in uence HC1 adjust.
790 / 791 optimis. at switch-on / off HC1 adjust.
834 servomotor travel time HC1 adjust.
850 / 851 oor drying HC1 adjust.
Heating circuit No. 2 (with 2
nd
circuit option)
= the warmest one (e.g.: radiators)
1010 comfort setpoint HC2 adjust.
1012 reduced setpoint HC2 adjust.
1020 heating curve slope HC2 adjust.
1041 ow temp setpoint max HC2 adjust.
1050 room in uence HC2 adjust.
1090 / 1091 optimis. at switch-on / off HC2 adjust.
1134 servomotor travel time HC2 adjust.
1150 / 1151 oor drying HC2 adjust.
Domestic Hot Water
1610 nominal DHW temp. setpoint DHW
1612 reduced DWH temp. setpoint DHW
1620 DHW release DHW
1640 to 1642 legionella cycle DHW
5024 DHW switch-on differ. DHW tank
5030 charging time limitation DHW tank
5061 heater release DHW tank
Setting Description Set to. Menus
Boiler backup (with "Boiler" kit option)
3700 OT.switch-on authoris. addit. gen.
3705 swith-off delay addit. gen.
Miscellaneous
6420 input H33 function 1 con guration
6100 OT sensor correction con guration
6120 frost protection on/off con guration
6205 reset settings con guration
6220 software version con guration
6711 reset heat pump error
Cooling (with "Cooling" kit option)
5711 cooling unit 2 pipes con guration
Faults (if a fault occurs, press"Info" key)
No. 10 outdoor sensor
No. 33 ow temp. sensor
No. 44 return temp. sensor
No. 50 DHW temp. sensor
No. 60 room sensor 1
No. 65 room sensor 2
No. 105 maintenance message
No. 121 HC1 ow T not reached
No. 122 HC2 ow T not reached
No. 127 leg. prot. T not reached
No. 369 external fault (EX3)
No. 370 outdoor unit connect error
6711 reset heat pump error
Heat pump
2844 switch-off temp max heat pump
2884 OT auth. to start elec. aux. heat pump
2920 Pk day clear (EX1) rel / lock heat pump
Swimming pool (with "swimming pool" kit option)
2056 generator setpoint Sw pool
Outdoor unit faults (see
page 66)
Waterstage Split Comfort DHW Serie / INSTALLATION / 2125 - EN