EasyManua.ls Logo

Fujitsu Waterstage Split Comfort 5 Series - Page 56

Fujitsu Waterstage Split Comfort 5 Series
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 56 -
Line Function
Setting range
or display
Setting
increment
Basic
setting
Heat pump (HP)
2779 I Pump speed max condenser pump cooling mode 70... 100 % 1 % 100 %
2793 I Pump speed max condenser pump 70... 100 % 1 % 100 %
2803 S Overrun time cond pump 8... 600 s 1 s 240s
2843 S Compressor o time min 0... 120 min 1 min 8 min
2844 S Switch-o temp max 8... 100 °C 1 °C 75 °C
2862 S Locking time stage 2 / mod 0... 40 min 1 min 5 min
2873 S Compressor mod run time 10... 600 s 1 s 240 s
2882 S Release integr electric ow 0... 500 °Cmin 1 °Cmin 100 °Cmin
2884 S Release el ow below OT
Electrical release - start-up with outdoor
temperature
-30... 30 °C 2 °C
2886 S Compensation heat de cit O , On,
Only with oor curing fct
O
2907 S Silent mode power max --, 1... 100 % 1 % --
2916 S Max setpoint HP DHW charg 8... 80 °C 1 °C --
2920 S With electrical utility lock (EX1)
(
g. 45, page 39)
Locked (Blocked on standby),
Released
Released
Released : HP = ON _ Back-up DHW = o _ 1
st
back-up HP = o _ 2
nd
back-up HP = o _ Boiler = ON
Locked (Blocked on standby) : HP = o _ Back-up DHW = o _ 1
st
back-up HP = o _ 2
nd
back-up HP = o _
Boiler = ON
3026 S Silent mode on 00:00... --:-- 10 min 22:00
3027 S Silent mode o 00:00... --:-- 10 min 07:00
3028 S Silent mode speed incr start -50... 50 °C 1 °C 8 °C
3029 S Silent mode speed incr end -50... 50 °C 1 °C 7 °C
Energy meter
3095 --> 3110 : Not used
3113 U Energy brought in Kwh --
Cumulation of total consumed electrical energy.
Electrical energy consumed = Electrical energy absorbed by outdoor unit + electric energy absorbed by the heating
electrical backup and / or DHW electrical backup (if installed).
3121 --> 3123 : Not used
3124 U Energy brought in heating 1 (N - 1) Kwh --
3125 U Energy brought in DHW 1 Kwh --
3126 U Energy brought in cooling 1 Kwh --
3128 --> 3130 : Not used
3131 U Energy brought in heating 2 (N - 2) Kwh --
3132 U Energy brought in DHW 2 Kwh --
3133 U Energy brought in cooling 2 Kwh --
3135 --> 3137 : Not used
3138 U Energy brought in heating 3 (N - 3) Kwh --
3139 U Energy brought in DHW 3 Kwh --
3140 U Energy brought in cooling 3 Kwh --
3142 --> 3144 : Not used
Note: "Energy" Counters increment as of 1 July each year.
Waterstage Split Comfort DHW Serie / INSTALLATION / 2125 - EN

Table of Contents