- (OU01 - 08) -
Outdoor unit / Single phase
OUTDOOR UNIT
WO
A060-100LF
OUTDOOR UNIT
WO
A060-100LF
Product information according to Commission Delegated Regulation (EU) 813/2013
Product information is based on the average climate condition.
Model
Hydraulic unit
WSYA100DG6
WSHA100DG *1
WGYA100DG6
WGHA100DG *1
WSYA100DG6
WSHA100DG *1
WGYA100DG6
WGHA100DG *1
Outdoor unit
WOYA080LFCA
WOHA080LFCA
WOYA100LFTA
WOHA100LFTA
Air-to-water heat pump Yes
Water-to-water heat pump No
Brine-to-water heat pump No
Low-temperature heat pump No
Equipped with a supplementary heater Yes
Heat pump combination heater Yes
Temperature application °C 55
35
55
35
55
35
55
35
Rated heat output *2
Prated
kW 6 7 6 7 8 8 8 8
Seasonal space heating energy efciency ƞ
s % 118 156 118 156 113 155 113 155
Declared capacity for heating for part load at indoor temperature 20 °C and outdoor temperature T
j
Tj = –7 °C Pdh kW 5.0 5.8 5.0 5.8 6.7 7.5 6.7 7.5
T
j = +2 °C Pdh kW 3.1 3.5 3.1 3.5 4.1 4.5 4.1 4.5
T
j = +7 °C Pdh kW 2.0 2.3 2.0 2.3 3.2 3.6 3.2 3.6
T
j = +12 °C Pdh kW 2.2 2.4 2.2 2.4 4.0 4.0 4.0 4.0
T
j = bivalent temperature Pdh kW 5.0 5.8 5.0 5.8 6.7 7.5 6.7 7.5
T
j = operation limit temperature Pdh kW 4.9 5.6 4.9 5.6 5.9 7.0 5.9 7.0
T
j = –15 °C (if TOL < –20 °C) Pdh kW - - - - - - - -
Bivalent temperature T
biv °C -7 -7 -7 -7 -7 -7 -7 -7
Cycling interval capacity for heating P
cych kW Not applicable
Degradation co-efcient *3 Cdh — 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9
Declared coefcient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature T
j
Tj = –7 °C
COPd
— 1.77 2.35 1.77 2.35 1.74 2.35 1.74 2.35
T
j = +2 °C
COPd
— 2.93 3.82 2.93 3.82 2.74 3.81 2.74 3.81
T
j = +7 °C
COPd
— 4.12 5.69 4.12 5.69 4.10 5.71 4.10 5.71
T
j = +12 °C
COPd
— 5.81 8.16 5.81 8.16 5.72 7.16 5.72 7.16
T
j = bivalent temperature
COPd
— 1.77 2.35 1.77 2.35 1.74 2.35 1.74 2.35
T
j = operation limit temperature
COPd
— 1.47 2.02 1.47 2.02 1.44 2.16 1.44 2.16
T
j = –15 °C (if TOL < –20 °C)
COPd
— - - - - - - - -
Operation limit temperature TOL °C -10 -10 -10 -10 -10 -10 -10 -10
Cycling interval efciency
COPcyc
— Not applicable
Heating water operating limit temperature
WTOL
°C 55 55 55 55 55 55 55 55
Power consumption in modes other than active mode
Off mode P
OFF kW 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005
Thermostat-off mode P
TO kW 0.016 0.030 0.016 0.030 0.022 0.043 0.022 0.043
Standby mode P
SB kW 0.009 0.009 0.009 0.009 0.008 0.008 0.008 0.008
Crankcase heater mode P
CK kW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Supplementary heater
Rated heat output *2 P
sup kW 0.8 0.9 0.8 0.9 1.7 1.4 1.7 1.4
Type of energy input Electric
Other items
Capacity control Variable
Sound power level
Indoor unit L
WA dB 46 46 46 46 46 46 46 46
Outdoor unit L
WA dB 65 69 65 69 68 69 68 69
Emissions of nitrogen oxides NO
x
mg/kWh
Not applicable
Rated air ow rate Outdoor unit — m³/h 1900 2340 1900 2340 3600 3600 3600 3600
Declared load prole - - L L - - L L
Daily electricity consumption Q
elec kWh - - 4.000 4.000 - - 4.000 4.000
Water heating energy efciency η
wh % - - 120 120 - - 120 120
Daily fuel consumption Q
fuel kWh Not applicable
Contact details
FUJITSU GENERAL (EURO) GmbH
Werftstraße 20, D-40549 Düsseldorf, F. R. Germany
*1 : Optional electrical back up heater consumption is taken into account in the performance calculation.
*2 : For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating
P
designh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup (Tj).
*3 : If Cdh is not determined by measurement then the default degradation coefcient is Cdh = 0.9.