Operation manual "1534 - EN"
Air to Water Heat Pump Split system
- 22 -
• ErP Denition
"ErP" includes two directives that are part of the program for the reduction of green house gas emission :
- Eco-design directive sets efency thresholds and prohibits the sale of any product with efciency lower than the set thresholds.
- According to labelling directive, energetic efciency shall be displayed to encourage end-users to purchase energy-efcient products.
• Package (Comfort models)
- application 35 °C
A
+++
A
++
G F E D C B A A
+
< 55% ≥ 55% ≥ 59% ≥ 61% ≥ 100% ≥ 107% ≥ 115% ≥ 123% ≥ 150% ≥ 175%
Models : Waterstage ... Comfort 5 Comfort 6 Comfort 8 Comfort 10
Hydraulic unit reference WSYA050DG6 WSYA100DG6 WSYA0100DG6 WSYA100DG6
Seasonal space heating energy efciency of heat
pump
169% 169% 156% 155%
Type of temperature control (* = Outdoor sensor ;** =
Room unit)
* class II ** class VI * class II ** class VI * class II ** class VI * class II ** class VI
Bonus 2% 4% 2% 4% 2% 4% 2% 4%
Seasonal space heating energy efciency of
package under average climate
171% 173% 171% 173% 158% 160% 157% 159%
Energy class of package A++ A++ A++ A++ A++ A++ A++ A++
Seasonal space heating energy efciency of
package under warmer climate
219% 221% 223% 225% 220% 222% 205% 207%
Seasonal space heating energy efciency of
package under colder climate
NA
The energy efciency of the package of products provided for in this che may not correspond to its actual energy efciency once installed in
a building, as the efciency is inuenced by further factors such as heat loss in the distribution system and the dimensioning of the products in
relation to building size and characteristics.
Electrical back up heater consumption is taken into account in the performance calculation.
- application 55 °C
A
+++
A
++
G F E D C B A A
+
< 30% ≥ 30% ≥ 34% ≥ 36% ≥ 75% ≥ 82% ≥ 90% ≥ 98% ≥ 125% ≥ 150%
Models : Waterstage ... Comfort 5 Comfort 6 Comfort 8 Comfort 10
Hydraulic unit reference WSYA050DG6 WSYA100DG6 WSYA050DG6 WSYA100DG6
Seasonal space heating energy efciency of heat
pump
115% 115% 118% 113%
Type of temperature control (* = Outdoor sensor ;** =
Room unit)
* classe II ** classe VI * classe II ** classe VI * classe II ** classe VI * classe II ** classe VI
Bonus 2% 4% 2% 4% 2% 4% 2% 4%
Seasonal space heating energy efciency of
package under average climate
117% 119% 117% 119% 120% 122% 115% 117%
Energy class of package A+ A+ A+ A+ A+ A+ A+ A+
Seasonal space heating energy efciency of
package under warmer climate
140% 142% 141% 143% 144% 146% 136% 138%
Seasonal space heating energy efciency of
package under colder climate
NA
The energy efciency of the package of products provided for in this che may not correspond to its actual energy efciency once installed in
a building, as the efciency is inuenced by further factors such as heat loss in the distribution system and the dimensioning of the products in
relation to building size and characteristics.
Electrical back up heater consumption is taken into account in the performance calculation.
ErP performance values