EasyManua.ls Logo

Fulling DZB200M - Feedback Settings and Disconnection Detection; Protection Parameters; Motor Overload Protection Settings

Default Icon
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Funct ion
Code
Nam e
SettingRange
Default
Valu e
F4.29
Multi-Speed 0
- 100.0 100.0%
0.0%
F4.30
Multi-Speed 1
- 100.0 100.0%
0.0%
F4.31
Multi-Speed 2
- 100.0 100.0%
0.0%
F4.32
Multi-Speed 3
- 100.0 100.0%
0.0%
F4. 3 3
Multi-Speed 4
-100.0 100.0 %
0.0%
F4.34
Multi-Speed 5
-100.0 100.0 %
0.0%
F4. 3 5
Multi-Speed 6
-100.0 100.0 %
0.0%
F4.36
Multi-Speed 7
-100.0 100.0 %
0.0%
Note: T he multi-spe e d sym bol define s t he oper at ion d i re ct ion . If it is negati ve, the o p er ation dire ctio n
is reverse. Frequency setting 100.0% is corresponding to maximu m freque ncy(F0.04).
Fig.6-20multi-speed l ogic D iagram
R el ati onship betwee n mul ti -s pee d and S term in a ls
1S2S3
、、
0: no protection. There is nomot oroverloadingpr otectioncharacteristic (caution to use ),andthereby the
inver ter has no pro te ction to the overloaded mo tor.
1: norma l motor (withlows peed compensati on).As general motorhas a poor heat em iss ion at low speed,
t he relevant e lectronic the rm al pr otec ti onshould be regulat edproperly.The low speed compensat ion
characteristic here mentioned is to sw it ch down t he overloading protectionthreshol dfo r the mo torw ith
anoperationfrequencylower than30 Hz.
2: Vari ablefrequenc y motor (without low speed compensation). As the heat emi ssi on of special variable
frequency motor is not affected bys peed, it i s no trequiredto r egulat e the protection value for low speed
ope r atio n .
F5 Protect ion P arameter s
S1
OFF
ON
OFF
ON
OFF
ON
OFF
ON
S2
OFF
OFF
ON
ON
OFF
OFF
ON
ON
S3
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Multi -S peed 0
Multi -S peed 1
Multi -S peed 2
Multi -S peed 3
Multi -S peed 4
Multi-Speed 5
Multi -S peed 6
Multi -S peed 7
Current segme nt o f multi-sp eed control
F5.0 0
Mot or O v erload
Prot ection O pt ion
0Noprotection
1 normal m otor
2 Variab le F requenc y motor
1
Fu nction
Code
Name
Setting Rang e
Default
Value
ON ON ON ON
ON O N
ON
1
2
3
4
5
6
7
0
S1
S2
S3
t
t
t
t
ON t
Output
fre quency
Operation
comma nd
Chapter 6 Parameter D escripti on
DZB Series
Chapter 6 Parameter Descr iption
DZB S eri es
-63- -64-
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT
BLUE ELEPHANT