INSTALLATION AND
OPERATION MANUAL
Vantage (VTG)
Condensing Hydronic Boilers
Standard, Dual Fuel, and Low Emissions Models
2,000,000 - 6,000,000 BTU/HR
504k - 1.5 MM kCal/HR
Serial/ National
Board Number
Model
Fulton Order
Owner
Site Name
Date
VTG-IOM-2016-1214

Table of Contents

Questions and Answers

  • B
    Brian WilliamsAug 9, 2025
    What to do if the pilot fails on my FULTON Boiler?
    • R
      Richard WilliamsAug 9, 2025
      If the pilot fails on your FULTON Boiler, several factors could be at play. Start by ensuring the manual shut-off valves are open, allowing gas to flow to the pilot tube. Then, adjust the incoming gas pressure and pilot gas pressure regulator to match the start-up report. If these steps don't resolve the issue, there may be air in the pilot gas line. In that case, allow the boiler to attempt lighting up to three times. If it still fails, it is recommended to call Fulton.
  • C
    Cynthia DayAug 28, 2025
    How to fix a FULTON Boiler when the control doesn't illuminate?
    • S
      Susan RasmussenAug 28, 2025
      If the control panel on your FULTON Boiler isn't lighting up, it's likely a power supply issue. Check the fuse or circuit breaker and reset or replace it as needed.
  • J
    Jason JenkinsNov 18, 2025
    Why won't the fan start on my FULTON Boiler?
    • S
      Samantha HensleyNov 18, 2025
      If the fan on your FULTON Boiler isn't starting, there are several potential causes: * A high temperature, low gas, or high gas trip may have occurred. In this case, try resetting the switch. If that doesn't work, the switch may need replacement. * The UT32A may be incorrectly set, preventing heat. Adjust the UT32A accordingly. * The flame detector may be detecting an extraneous light source. Identify and remove the light source. If the problem persists, replace the flame detector. * The air switch may be activated when the fan is off. Try resetting the switch, and if that doesn't work, replace it. * The blower contactor might be engaged when the fan is off. If so, replace the motor contactor. * A defective gas valve proof of closure can also prevent the fan from starting. Rep...

Summary

INTRODUCTION

Warnings & Cautions

Critical safety information to prevent injury, death, or equipment damage.

OPERATION

Pre-Start-Up, System Fill & Commissioning

Steps for initial inspection, system filling, purging, and boiler commissioning.

Safety System Testing & General Operation

Testing safety controls and guidelines for efficient boiler operation.

MAINTENANCE

Annual Maintenance & Component Inspection

Annual tasks, filter cleaning, burner, and flue passage inspections.

Troubleshooting Guide

A comprehensive guide to diagnosing and resolving common boiler issues.

WARRANTY & PARTS

Standard Warranty Terms & Conditions

Details of warranty coverage, exclusions, and conditions for Fulton boilers.

Lifetime & Vessel Warranties

Specific warranty coverage for thermal shock and pressure vessel failures.

INTRODUCTION (ModSync)

OPERATION (ModSync)

NETWORK (ModSync)

MAINTENANCE (ModSync)

ModSync Alarms & Troubleshooting

Explains ModSync alarms, troubleshooting common issues, and program backup.

PARTS AND WARRANTY (ModSync)

FULTON Vantage VTG 3000 Specifications

General IconGeneral
BrandFULTON
ModelVantage VTG 3000
CategoryBoiler
LanguageEnglish