INSTALLATION AND
OPERATION MANUAL
Vantage (VTG)
Condensing Hydronic Boilers
Standard, Dual Fuel, and Low Emissions Models
2,000,000 - 6,000,000 BTU/HR
504k - 1.5 MM kCal/HR
Serial/ National
Board Number
Model
Fulton Order
Owner
Site Name
Date
VTG-IOM-2016-1214

Table of Contents

Questions and Answers

  • K
    karengonzalezAug 9, 2025
    What to do if the pilot fails on my FULTON Boiler?
    • M
      marilynknappAug 9, 2025
      If the pilot fails on your FULTON Boiler, several factors could be at play. Start by ensuring the manual shut-off valves are open, allowing gas to flow to the pilot tube. Then, adjust the incoming gas pressure and pilot gas pressure regulator to match the start-up report. If these steps don't resolve the issue, there may be air in the pilot gas line. In that case, allow the boiler to attempt lighting up to three times. If it still fails, it is recommended to call Fulton.
  • M
    martinezdavidAug 29, 2025
    How to fix a FULTON Boiler when the control doesn't illuminate?
    • D
      Denise GonzalezAug 29, 2025
      If the control panel on your FULTON Boiler isn't lighting up, it's likely a power supply issue. Check the fuse or circuit breaker and reset or replace it as needed.
  • J
    John ChambersNov 17, 2025
    Why won't the fan start on my FULTON Boiler?
    • V
      victorialongNov 17, 2025
      If the fan on your FULTON Boiler isn't starting, there are several potential causes: * A high temperature, low gas, or high gas trip may have occurred. In this case, try resetting the switch. If that doesn't work, the switch may need replacement. * The UT32A may be incorrectly set, preventing heat. Adjust the UT32A accordingly. * The flame detector may be detecting an extraneous light source. Identify and remove the light source. If the problem persists, replace the flame detector. * The air switch may be activated when the fan is off. Try resetting the switch, and if that doesn't work, replace it. * The blower contactor might be engaged when the fan is off. If so, replace the motor contactor. * A defective gas valve proof of closure can also prevent the fan from starting. Rep...

Summary

Introduction

Warnings & Cautions

Highlights critical safety information to prevent injury, death, or equipment damage.

Installation

Placement & Rigging

Provides essential guidelines for proper placement and safe rigging of the boiler.

Clearances and Serviceability

Details required clearances for safe operation, maintenance, and access around the boiler.

Meet Water Chemistry Requirements

Specifies system water chemistry requirements to prevent corrosion and scale.

Install Gas Piping

Guidelines for installing natural gas piping for the boiler.

Venting

General requirements for exhaust and air intake venting systems.

Exhaust Venting

Requirements for installing the exhaust venting system.

Operation

Maintenance

FULTON Vantage VTG 6000DF Specifications

General IconGeneral
CategoryBoiler
Fuel TypeNatural Gas or Propane
ModelVantage VTG 6000DF
Input Range6, 000, 000 BTU/hr
Thermal Efficiency85%
Operating Pressure160 PSI
ConstructionSteel