APPENDIX
AP-10
DISP port
Baud rate selectable from 4800 and 38400 (bps).
Blue Sign port
Sentence description
Input sentences
ABM - Addressed binary and safety related message
ACA - AIS regional channel assignment message
LTC1535C
GND2GND
RD
TD
GND
110Ω
DISP_RD_B
DISP_RD_A
DISP_TD_B
DISP_TD_A
GND_ISO
TLP181
RD
5V
Blue Sign_H
Blue Sign_C
270 ohm
!**ABM, x, x, x, xxxxxxxxx, x, x.x, s--s, x, *hh<CR><LF>
1 2 3 4 5 6 7 8
1. Total number of sentences needed to transfer the message (1 - 9)
2. Message sentence number (1 - 9)
3.
Message sequence identifier (0 - 3)
4. The MMSI of destination
AIS unit for the ITU-R M.1371 message (9 digits)
5. AIS channel for broadcast of the radio message (0 - 3)
6. VDL message number (6 or 12), see ITU-R M.1371
7. Encapsulated data (1 - 63 bytes)
8.
Number of fill-bits (0 - 5)
9. Channel B
10. Channel B bandwidth
11. Tx/Rx mode control
12.
Power level control
13. Information source
14. In-use flag
15. T
ime of “in-use” change
1. Sequence number, 0 to 9
2. Region Northeast corner latitude - N/S
3.
Region Northeast corner longitude - E/W
4. Region Southwest corner latitude - N/S
5. Region Southwest corner longitude - E/W
6. T
ransition Zone Size
7. Channel A
8. Channel A bandwidth
$**ACA,x,IIII.lI, a,yyyyy.yy,a,IIII.II,a,yyyyy.yy,a,x,xxxx,x,xxxx,x,x,x,a,x,hhmmss.ss,*hh<CR><LF>
1 2 3 4 5 6 7 8
9 1011121314
15