6.1 Self-test
6-3
3. Press the [F1] key 2 times to go to the next screen.
4.
This screen displays the input sentences of serial ports.
Fig. 6.1.2 Example of Self-Test NMEA Check Screen
5. Press the [F1] key after checking.
6. The screen goes to the input sentence screen of the AIS and the INS. See page.6-10.
7. Press the [F1] key to return to the original screen after checking.
6.1.2 Description
1. Self-test screen-1
Display of program numbers
All types of S-band and X-band radars use the same program.
Table 6.1.1 Display of Program Numbers
Display Applicable program Program number
SPU
Processor unit
(SPU Board: MAIN, ARPA, DRAW CPU)
0359204-02.xx
RFC Transceiver unit (RFC Board: RFC CPU) 0359202-01.xx
KEY Standard control unit: RCU-014
REMOTE 1 Trackball unit: RCU-015
REMOTE 2 Remote control unit: RCU-016
0359203-01.xx
CARD Card I/F unit: CU-200 0359209-01.xx
There is no restriction on the display b