2-1
2. WIRING
Wiring of FELCOM19
Power supply
12-24 VDC
Copper strap
1.2 m
Ground wire
RW-4747
TP5FBAW-5DFB, 30 m
(No armor)
Connector at both ends
0.34 m
For cable w/armor
TNCP-NJ
Cable assy
TPA5FB0.4NJ5FBA-5DFB
0.4 m
LAN cable
PC
CAUTION
MJ-A3SPF0016-035
5D-FB-CV-NP, 30 m
8D-FB-CV, 50 m
12D-SFA-CV, 100 m
Connector at one end
Connector N-P-5DFB
N-P-12DSFA
N-P-8DFB
(supplied, local arrange)
This unit is shipped with a 10 A fuse, which
is for use with a 12 VDC power supply. For
24 VDC power, replace the fuse with a 5A
fuse.
Attach the label for 5 A to the fuse cover on
the power cable.
Use of wrong fuse can result in damage to
the equipment.