2. WIRING
15
2.2 Distress Alert/Received Call Unit IC-305
Use the installation material CP16-02201 to connect the distress alert IC-305.
The optional CO-SPEVV-SB-C 0.2x5P cable or JIS cable (Japan Industrial
Standards) TTYCS-4 or equivalent are available to connect with the junction box
IC-305. Select the cable clamp attached depending on the diameter of cable,
and fix the armor of cable with the clamp.
Painting
Armor
(Sectional view)
S =1.25 mm
=1.35 mm
2
Conductor
(Twisted pair)
Shield
Vinyl sheath
TTYCS-4 cable, sectional view
Distress alert
IC-305
16P0213
12345
1: FV1.25-3, red
2: FV1.25-3, red
3: FV1.25-3, red
4: FV1.25-3, red
5: Shield (FV2-3, blue)
15 mm 40 mm 10 mm
CO-SPEVV-SB-C 0.2X5P
or TTYCS-4
Cut unused cables.
For TTYCS-4 (JIS)
or equivalent
For CO-SPEVV-
SB-C 0.2x5P 16S0344
Twist the shield.
Crimp-on lug to use
Wiring of distress alert IC-305