3.2 Setting for External Equipment
The FELCOM 15 system had been set to accommodate to distress alert/received call unit
IC-305, alarm unit IC-306 and distress message controller DMC-5 at factory. If less than
three units are connected, change the setting to OFF as below.
1. Press the [F8] key to show the Setup menu.
2. Press the [2] key to show the System Setup menu.
3. Press the [] key to select “Command Window”, and then press [Enter] key to show the
Command Window screen.
4. Referring to the service manual for FELOM15, fill in the “Enter JOB No.:” and then press
the [Enter] key.
5. As similar to step 4, fill in the “PASSWORD:”, and then press the [Enter] key.
[Main Menu] is highlighted.
6. Press the [1] and [Enter] keys in order.
Setup
9. Configuration
System Setup
01:53 02-02-25 (YY-MM-DD)
INMARSAT-C
OFF
INT
INT
INT
System Date & Time
IMN
MES Operation Mode
Nav Port
Active Port
Message Output Port
EGC Output Port
Network Setup
Command Window
Command Window
[ Main Menu ]
1. Remote Box Setup
2. Internal GPS Setup
Enter JOB No.: 1
[ Remote Box Setup ]
1. DMC ON
2. IC-305 ON
3. IC-306 No.1 ON
4. IC-306 No.2 ON
5. IC-306 No.3 ON
E: Exit
Enter No.:
Command Window screen
7. Press the number key for unit not connected, and then press the [Enter] key.
For example, press the [1] and [Enter] keys when the DMC-5 is not connected.
[ DMC ]
1. ON
2. OFF E: Exit
Enter No.:
Setting window for DMC-5
8. Press the [2] key, and the [Enter] key.
Instead of a numeric key, press the [E] key to return to Remote Box Setup menu.
9. Repeat steps 7 to 8 for other unit not connected.
10. Press the [Esc] key several times to close the menu.