24
5. CHANGING SHIP’S MAINS
SPECIFICATIONS
The power supply PR-240-CE (option) is shipped with 220 VAC (200-230 VAC) setting. If
the ship’s mains is 100 VAC – 115 VAC, change the top connection and terminal connection
as follows.
Ship’s mains Tap connection
Terminal board
connection # 1& #2
Power supply label
100-115 VAC SEL 115 V b
100-115 VAC 2.3-2.0A
1φ 50/60 kHz
200-230 VAC SEL 230 V a
200-230 VAC 1.15-1.0 A
1φ 50/60 kHz
1
2
3
4
5
6
7
8
Heat sink
Tap connection
(Disconnect and plug into appropriate location.)
Front
SEL
115 V
SEL
230 V
Top view (Cover removed)
1
2
3
100-115 VAC
1
2
3
200-230 VAC
Terminal board connection
(a)
(b)
White
Black
White
Black
Attach the appropriate label.