99
0RGHO0HQX$LUSODQH*OLGHU)XQFWLRQV!
6HWWLQJPHWKRG
3ULRUWRXVLQJWKH)XQFWLRQPHQXLQWKH/LQNDJHPHQXWR
DVVLJQWKHVHQVLWLYLW\FKDQQHO*\UR*\UR*\URVHOHFWDQ
unused channel.
Set [Control] and [Trim] other than function to [--].
Ɣ5DWHVHWXSVFUHHQVHOHFWLRQ
Move the cursor to the setup screen selection
item and touch the RTN button to switch
to the data input mode. Select the setup
screen # by scrolling the touch sensor.
Touch the RTN button to change the setup
screen and return to the cursor mode.
Ɣ$FWLYDWHWKHIXQFWLRQ
Move the cursor to the [INH] item and touch
the RTN button to switch to the data input
mode. Select the ACT mode by scrolling the
touch sensor.
*The display blinks.
Touch the RTN button to activate the
function and return to the cursor mode.
When setting a rate selection switch, move
the cursor to the switch item and touch the
RTN button to access the selection screen.
Select the switch and set its ON direction.
(Always ON at "--" setting)
)RUDGHVFULSWLRQRIWKHVZLWFKVHOHFWLRQPHWKRGVHHWKH
description at the back of this manual.
Ɣ*\URW\SHVHOHFWLRQ
Move the cursor to the gyro type selection
item and touch the RTN button to switch to
the data input mode. Select the gyro type
by scrolling the touch sensor.
[GY]: When a Futaba GYA gyro is used
[NORM]: When using something other than
Futaba GYA gyro is used.
Touch the RTN button to change the gyro
type and return to the cursor mode.
:KHQD)XWDED*<$J\URLVXVHGDQG>*<@W\SHLVVHOHFWHG
the sensitivity set value is directly read in both the AVCS
DQG1250PRGHV
Ɣ2SHUDWLRQPRGHVHOHFWLRQ*<$J\UR
Move the cursor to the operation mode
selection item and touch the RTN button
to switch to the data input mode. Select
the operation mode by scrolling the touch
sensor.
[AVCS]: AVCS mode
[NORM]: Normal mode
Touch the RTN button to change the
operation mode and return to the cursor
mode.
Ɣ6HQVLWLYLW\VHWWLQJ
Move the cursor to the sensitivity item and
touch the RTN button to switch to the data
input mode.
Adjust the sensitivity by scrolling the touch
sensor.
,QLWLDOYDOXH
$GMXVWPHQWUDQJHa
:KHQWKH571EXWWRQLVWRXFKHGIRURQHVHFRQGWKH
VHQVLWLYLW\LVUHVHWWRWKHLQLWLDOYDOXH
Touch the RTN button to return to the cursor
mode.