18 user manual GSC_4
3.4 Recalling the bank
3.5 Controller’s hardware work
Press the UP and DOWN foot switches simultaneously to change between preset and bank switching.
Backlight color will change depending on the function. Red color for bank switching and green color for
preset switching. In bank switching every press of the UP and DOWN foot switches will change the bank.
For a faster change of banks press and hold down the UP or DOWN foot switches.
Bank will also change when the preset will be changed from 9 to 0 (one bank UP) and from 0 to 9 (one
bank DOWN).
Recalling a PRESET or the LOOP MODIFIER (using the MFS footswitches or preset UP/DOWN in direct mode)
will cause the relays to switch. Relays will not switch when a recalled preset or MFS doesn’t change the
LOOP’S state. In the first stage the signal is muted. Then relays are switched and muting is off.
Recalling a PRESET or the SWITCH MODIFIER (using the MFS footswitches or preset UP/DOWN in direct
mode) will cause the relays to switch. Relays will not switch when recalled preset or MFS doesn’t change
the SWITCH OUTS state. Relay mode operation depends on the setting (see chapter 4.2.3).
Recalling a PRESET or the MIDI MODIFIER (using the MFS footswitches or preset UP/DOWN in direct mode)
couldcausesendingofMIDIcommands.CommandordercorrespondstotheprogrammedMIDIDEVICE
list. If PROGRAM and CONTROL CHANGE are assigned for one midi device the PROGRAM CHANGE is sent
as first by default. For more PC and CC order see the chapter 4.2.1
3.5.1 LOOPS
3.5.2 SWITCH outs
3.5.3 MIDI