4. Irrigaon Programming
1. Open the top cover.
2. Set the irrigaon me selector to the desired irrigaon duraon.
3. Set the irrigaon cycle me selector to the desired cycle me.
4. Press the "START" switch.
The tap will open immediately and the irrigaon will commence, for
the set duraon and cycle mes.
For example:
• If you set the irrigaon cycle me selector to "1 Day" and the
irrigaon me selector to "30 MIN". The tap will open immediately
upon pressing the "START” switch and will remain open for 30
minutes. The tap will open at the same me on the following day
for 30 minutes everyday.
The tap will open every day at the me you pressed the switch on
the rst day.
Please note: You can change the irrigaon duraon and the cycle
me even aer you acvate the program by changing the sengs
of the selectors.
5. Programming an Irrigaon
Controller with a Delayed
Opening Time
For Example, a 3 Hr irrigaon, once every 3 days program,
programmed to start 6 Hr later.
1. Set the irrigaon me selector to 3 Hr.
2. Set the irrigaon cycle me selector to "Delay".
3. Press and hold the "START* switch unl you hear G clicks,
including the rst click, (the number of clicks corresponds to the
number of delay hours before the controller opens the tap for the
rst me).
4. Set the irrigaon cycle me selector to "3 Days".
When you set an odd number of delay hours you will hear an
addional click a few seconds aer releasing the switch. This click
keeps the tap closed unl its rst opening.
*To change the opening hour, remove the baeries for 3 minute.
Program the controller from the start aer replacing the baeries.
6. Maintenance
Remove the baery if the irrigaon controller will not be used for a
prolonged me. Remove the lter and clean it periodically (every
few months). Failure to clean the lter may cause problems.