This height applies either side of the orthogonal projecon of the outermost conductors of the power
line on the ground surface, for a distance of:
- 2 m for power lines operang at a nominal voltage not exceeding 1 000 V;
- 15 m for power lines operang at a nominal voltage exceeding 1 000 V.
• Electric animal fences intended for deterring birds, household pet containment or training animals
such as cows need only be supplied from low output energizers to obtain sasfactory and safe
performance.
• In electric animal fences intended for deterring birds from roosng on buildings, no electric fence wire
shall be connected to an earth stake. A warning sign shall be ed to every point where persons may
gain ready access to the conductors.
• Where an electric animal fence crosses a public pathway, a non-electried gate shall be incorporated
in the electric animal fence at that point or a crossing by means of sles shall be provided. At any such
crossing, the adjacent electried wires shall carry warning signs.
• Any part of an electric animal fence that is installed along a public road or pathway shall be idened
by electric fence warning signs (G6020) at regular intervals that are securely fastened to the fence
posts or rmly clamped to the fence wires.
• The size of the warning sign shall be at least 100mm x 200mm.
• The background colour of both sides of the warning sign shall be yellow. The
inscripon on the sign shall be black and shall be either:
-the substance of “CAUTION: Electric Fence” or,
-the symbol shown:
• The inscripon shall be indelible, inscribed on both sides of the warning sign
and have a height of at least 25mm.
• Ensure that all mains operated, ancillary equipment connected to the electric animal fence circuit
provides a degree of isolaon between the fence circuit and the supply mains equivalent to that
provided by the energizer.
• Protecon from the weather shall be provided for the ancillary equipment unless this equipment is
cered by the manufacturer as being suitable for use outdoors, and is of a type with a minimum
degree of protecon IPX4.
This energizer complies with internaonal safety regulaons and is manufactured to internaonal
standards.
Gallagher reserves the right to make changes without noce to any product specicaon to improve
reliability, funcon or design. E & OE.
The author thanks the Internaonal Electrotechnical Commission (IEC) for permission to reproduce
Informaon from its Internaonal Publicaon 60335-2-76 ed.2.2 (2013). Annex BB.1. All such extracts are
copyright of IEC, Geneva, Switzerland. All rights reserved. Further informaon on the IEC is available from
www.iec.ch. IEC has no responsibility for the placement and context in which the extracts and contents are
reproduced by the author, nor is IEC in any way responsible for the other content or accuracy therein.
Save these instrucons.