RTxxx LEDlighting controllers - User Manual
Note: parameters are in USA/UK format so that a half is written ‘0.5 not
‘0,5’. For example:
Parameter Meaning
0.1 0.1 millisecond
200μs 200 microseconds
0.1s 0.1seconds
100ma 100mA
2.45A 2.45A
2.3 2300mA or 2.3A
The command codes and their meaning are described in Section 12.3.1,
General commands. The upper case commands are shown, followed by
lower case letters denoting the numeric argument.
12.3.1 General commands
Any changes you make using Ethernet commands are not saved
permanently until you send the AW command.
Report the version of firmware running in the RTxxx
This command returns the firmware version. For example:
VR returns
RT420-20 (HW02) V031
Set Internal Trigger
Enable or disable the internal trigger. When enabled, all outputs are
triggered simultaneously using an internal trigger signal. This setting
can be saved to non-volatile memoryusing the AW command.
TT0
Disable internal trigger
TT1
Enable internal trigger (uses previously
set period)
TT1,p
Enable internal trigger and set the
period
Where:
P = period of the triggers in milliseconds
For example:
TT1,200
Set the internal trigger to 200ms (5Hz)
TT1,500US
Set the internal trigger to 500μs (2KHz)