2
IMPORTANT
When carrying out commissioning of the boiler, you are highly recommended to perform the following checks:
Make sure that there are no liquids or inflammable materials in the immediate vicinity of the boiler.
Make sure that the electrical connections have been made correctly and the earth wire is connected to a
weel done earthing system.
Open the gas tap and check the soundness of the connections, including the burner.
Make sure that the boiler is set for operation for the type of gas supplied.
Check that the flue pipe for the outlet of the products of the combustion is unobstructed and has been properly
installed.
Make sure that any shutoff valves are open and dirt seperators are installed on the return water connection.
Make sure that the system is charged with water and is thoroughly vented.
Check that the circulation pump is not locked.
Purge the system, bleeding off the air present in the gas pipe by operating the pressure relief valve on the gas
valve inlet.
The installer must provide the user with instruction in operation of the boiler and safety devices and hand over the
instruction booklet to the user.
The images shown in this manual are a simplified representation of the product. In this representation there may be
slight, unimportant differences with the supplied product.
1 Meaning of the symbols and safety instructions . . 3
1.1 Meaning of symbols
1.2 General warnings
2 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.1 Designated use . . . . . . . . . . . . . . . . . . . . . 5
2.3 . . . . . 5Boiler room & ventilation. . . . . . . . . .
2.2 Description of the appliance . . . . . . . . . . 5
. . . . . . . . . . . . . . . . . . 3
. . . . . . . . . . . . . . . . . . . 3
1.3 Safety instructions
. . . . . . . . . . . . . . . . . . . 4
1.4 Regulations and standarts
. . . . . . . . . . . . 4
2.4 Packaging label . . . . . . . . . . . . . . . . . . . . . 6
2.5 . . . . . . . . . . . . . . . . . . . . . . 6Warning label
2.6 Data label . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.1 Wallcon 42/50/67 dimensions . . . . . . . . . 7
3.2 . . . . 8Wallcon 42/50/67 hydraulic diagram
3.3 Wallcon 42/50/67 main components . . . . . . . 9
3 Technical features . . . . . . . . . . . . . . . . . . . . . . . . 7
3.4 Technical data . . . . . . . . . . . . . . . . . . . . . .. 10
4.1.1 Packing . . . . . . . . . . . . . . . . . . . . . . . . 11
4 Instructions for the installer . . . . . . . . . . . . . . . . . . . 11
4.1 . . . . . . . . . . . . . . . . . . . . . . . . 11Installation
4.1.2 Transport . . . . . . . . . . . . . . . . . . . . . . 11
4.1.3 Mounting . . . . . . . . . . . . . . . . . . . . . . . 11
4.1.4 Clearances . . . . . . . . . . . . . . . . . . . . . 12
4.1.6 Water side connections . . . . . . . . . . . . 13
4.1.5 Water quality and treatment . . . . . . . . . 12
4.1.7 Expansion vessel . . . . . . . . . . . . . . . . . 13
4.1.8 Safety valve . . . . . . . . . . . . . . . . . . . . 13
4.1.9 Condansate drain . . . . . . . . . . . . . . . . 13
4.1.10 Frost protection . . . . . . . . . . . . . . . . . 13
4.1.11 Dirt seperation . . . . . . . . . . . . . . . . . . 13
4.1.13 Pump . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.1.12 Automatic air vent . . . . . . . . . . . . . . . . 13
4.2 Installation examples . . . . . . . . . . . . . . . . 14
4.2.1 Single boiler installations . . . . . . . . . . . 14
4.2.2 Cascade installation . . . . . . . . . . . . . . . . 15
4.3 Adjustment of the gas rate . . . . . . . . . . . 16
4.3.1 Description of the adjustment points . . . 16
4.3.2 Combustion values adjustment table . . . 16
4.3.3 Maximum output adjustment . . . . . . . . . 16
4.3.4 Minimum output adjustment . . . . . . . . . 17
4.4 Gas conversion instructions . . . . . . . . . . . 18
4.5 Flue installation instructions . . . . . . . . . . . 19
4.5.1 Flue appliance types . . . . . . . . . . . . . . . 19
4.5.2 Flue installation types . . . . . . . . . . . . . . 20
4.5.3 Flue kit accesories . . . . . . . . . . . . . . . . . 21
4.6 Electrical installation . . . . . . . . . . . . . . . . 22
4.6.1 Wiring diagram . . . . . . . . . . . . . . . . . . . . 22
4.6.2 External probe installation . . . . . . . . . . 23
4.6.3 Outdoor temperature control . . . . . . . . 24
5 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5.2 Programming . . . . . . . . . . . . . . . . . . . . . 27
5.3 Error codes . . . . . . . . . . . . . . . . . . . . . . 28
5.4 Maintenance codes . . . . . . . . . . . . . . . . 29
6 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
6.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Comissioning checklist . . . . . . . . . . . . . . . . . . 34
6.2 Maintenance procedure . . . . . . . . . . . . . 30
Service interval record . . . . . . . . . . . . . . . . . . 37
6.3 Troubleshooting . . . . . . . . . . . . . . . . . . . 32

Related product manuals