EasyManuals Logo

GE Interlogix NX-8 - Security NetworX System User Manual

GE Interlogix NX-8 - Security NetworX System
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background image
Page 39
LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA
L
19 16 DOWNLOAD ACCESS CODE
8-4-8-0-0-0-0-0
________
L
20 16 RINGS TO ANSWER DOWNLOAD
8
_
DOWNLOAD CONTROL
Segment #1 (Circle Numbers To Program)
L
21 16
1
2
3
4
5
6
7
8
Enables two call answering machine defeat
Enables tone sniff answering machine defeat
Requires callback before downloading
Shutdown control panel
Lock out local programming
Lock out communicator programming
Lock out download section
Enables callback at autotest interval
L
22 16 CALLBACK PHONE NUMBER
14-14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-14
__ __ __ __ __ __ __ __ __ __
__ __ __ __ __ __ __ __ __ __
PARTITION #1, FEATURE SELECTION
L
23 17
Segment #1 Segment #2 Segment #3
1
2
3
4
5
6
7
8
Quick Arm
Re-Exit
Auto Bypass
Silent Panic
Audible Panic
Auxiliary 1
Auxiliary 2
Multi Keypress Tamper
1
2
3
4
5
6
7
8
LED extinguish enable
Require user code for bypassing zones
Bypass sounder alert
AC power/low battery sounder alert
Enables bypass toggle
Enables silent auto arm
Enables automatic instant
Reserved
1
2
3
4
5
6
7
8
Open/Close
Bypass
Restore
Trouble
Tamper
Cancel
Recent Closing
Exit Error
ENTRY/EXIT TIMERS
Segment #1 (Entry Time #1)
30
Segment #2 (Exit Time #1)
60
Segment #3 (Entry Time #2)
30
L
24 17
Segment #4 (Exit Time #2)
60
L
25 19 ZONES 1-8, ZONE TYPES
3-5-6-6-6-6-6-6 ________
ZONES 1-8, PARTITION SELECTION (Segment 1=Zone 1 thru Segment 8=Zone 8)
Segments 1 2 3 4 5 6 7 8
26 19
Partition #1
Partition #2
Partition #3
Partition #4
Partition #5
Partition #6
Partition #7
Partition #8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Interlogix NX-8 - Security NetworX System and is the answer not in the manual?

GE Interlogix NX-8 - Security NetworX System Specifications

Power IconPower
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
auxiliary power with NX-320 power supply12 VDC Regulated 2 AMPS + Control
Loop Specifications IconLoop Specifications
standard loop resistance300 Ohms Maximum
2-wire smokes resistance30 Ohms Maximum
loop responseSelectable 50mS or 500mS
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
built-in siren driver2-tone (Temporal and Yelp)
LED keypad current draw130 mA max.
Weight and Dimensions IconWeight and Dimensions
metal enclosure dimensions11.25" Wide x 11.25" High x 3.50" Deep
shipping weight9 lbs.
LED keypad dimensions6.4" Wide x 4.0" High x 1.1" Deep
NX-148 LCD keypad dimensions6.4" Wide x 5.3" High x 1.0" Deep

Related product manuals