11-140 869 MOTOR PROTECTION SYSTEM – COMMUNICATIONS GUIDE
MODBUS MEMORY MAP CHAPTER 11: MODBUS MEMORY MAP
81509 0xA224 Down 0 0xFFFFFFFF 1 FC142 0 1
81511 0xA226 Set to Pre-set 0 0xFFFFFFFF 1 FC142 0 1
81513 0xA228 Reset 0 0xFFFFFFFF 1 FC142 0 1
81515 0xA22A Freeze/Reset 0 0xFFFFFFFF 1 FC142 0 1
81517 0xA22C Freeze/Count 0 0xFFFFFFFF 1 FC142 0 1
81519 0xA22E Block 0 0xFFFFFFFF 1 FC142 0 1
81521 0xA230 HI 4 Output Relays 0 0xFFFFFFFF 1 FC198 0 1
81523 0xA232 EQL 4 Output Relays 0 0xFFFFFFFF 1 FC198 0 1
81525 0xA234 LO 4 Output Relays 0 0xFFFFFFFF 1 FC198 0 1
81527 0xA236 Events 0 1 1 FC126 1 1
Digital Counter 5
81528 0xA237 Function 0 1 1 FC126 0 1
81529 0xA238 Name 0 65535 1 F60_26 Counter 5 26
81542 0xA245 Units 0 65535 1 F60_6 units 6
81545 0xA248 Pre-set -2147483648 2147483647 1 F30 0 1
81547 0xA24A Compare -2147483648 2147483647 1 F30 0 1
81549 0xA24C Up 0 0xFFFFFFFF 1 FC142 0 1
81551 0xA24E Down 0 0xFFFFFFFF 1 FC142 0 1
81553 0xA250 Set to Pre-set 0 0xFFFFFFFF 1 FC142 0 1
81555 0xA252 Reset 0 0xFFFFFFFF 1 FC142 0 1
81557 0xA254 Freeze/Reset 0 0xFFFFFFFF 1 FC142 0 1
81559 0xA256 Freeze/Count 0 0xFFFFFFFF 1 FC142 0 1
81561 0xA258 Block 0 0xFFFFFFFF 1 FC142 0 1
81563 0xA25A HI 5 Output Relays 0 0xFFFFFFFF 1 FC198 0 1
81565 0xA25C EQL 5 Output Relays 0 0xFFFFFFFF 1 FC198 0 1
81567 0xA25E LO 5 Output Relays 0 0xFFFFFFFF 1 FC198 0 1
81569 0xA260 Events 0 1 1 FC126 1 1
Digital Counter 6
81570 0xA261 Function 0 1 1 FC126 0 1
81571 0xA262 Name 0 65535 1 F60_26 Counter 6 26
81584 0xA26F Units 0 65535 1 F60_6 units 6
81587 0xA272 Pre-set -2147483648 2147483647 1 F30 0 1
81589 0xA274 Compare -2147483648 2147483647 1 F30 0 1
81591 0xA276 Up 0 0xFFFFFFFF 1 FC142 0 1
81593 0xA278 Down 0 0xFFFFFFFF 1 FC142 0 1
81595 0xA27A Set to Pre-set 0 0xFFFFFFFF 1 FC142 0 1
81597 0xA27C Reset 0 0xFFFFFFFF 1 FC142 0 1
81599 0xA27E Freeze/Reset 0 0xFFFFFFFF 1 FC142 0 1
81601 0xA280 Freeze/Count 0 0xFFFFFFFF 1 FC142 0 1
81603 0xA282 Block 0 0xFFFFFFFF 1 FC142 0 1
81605 0xA284 HI 6 Output Relays 0 0xFFFFFFFF 1 FC198 0 1
81607 0xA286 EQL 6 Output Relays 0 0xFFFFFFFF 1 FC198 0 1
81609 0xA288 LO 6 Output Relays 0 0xFFFFFFFF 1 FC198 0 1
81611 0xA28A Events 0 1 1 FC126 1 1
Digital Counter 7
81612 0xA28B Function 0 1 1 FC126 0 1
Modbus
Address
Hex
Address
Description Min Max Step Units Format
Code
Factory
Default
Size in
Words