Aboutthe controlsonthedehumidifier.
4houror2hour High,Medium
delayoff andLowfan
indicatorlights indicatorlights
Cleanthe Filter Continuousoperationon
indicatorlight indicatorlight
4 hour
2 hour
High
Mediul
Low
Humiditg %
o-
Continuous
Cteen the Filter
e,
Bucket Full
Power On
BucketFulllightindicates
bucketneedstobeemptied
orisnot inplaceintheunit
]
PowerOn
indicatorlight
4
Controls
NOTE:When the bucket isfull or removed,the
controls cannot be set.
Power Pad
Pressto turn the dehumidifier on and off.
Filter Timer
After 250 hoursof operation,the CleantheFilter
indicGtorlightwill glow to remindyou to clean
the filter.Removethe filter and clean it.
Pressto turn off the CleantheFilterlight.See
the Careand Cleaningsection.
Humidity Set Control Pads
Thehumidity level can be set within a range of
35% RH(RelativeHumidity)to 80% RH(Relative
Humidity) in 5% increments or at COlor
continuous operation. To set the unit for
continuous operation, pressthe T pad until
the screen reads CO.
NOTE:If CO(Continuous)isselected,the
dehumidifier will operate continuously at
its maximum dehumidification settings if
attached to a hoseto drain or until the bucket
isfull.
Fordrier air, pressthe V pad and set to
a lower percent value (%).
Fordamper air, pressthe A pad and set
to a higher percent value (%).
Other,Features
When you first use the dehumidifier, set
the humidity control to 45% or 50%.Allow at
least 24 hours for the dehumidifier to achieve
the humidity level.Ifyou still have dumper air
than desired,set the humidity level to a lower
setting or select Continuousfor maximum
dehumidification.
Display
Shows the set % humidity levelwhile setting,
then shows the actual (+/- 5% accuracy)
room % humidity level.
Fan Speed Pad
Controls the fan speed.
Pressto select either High,Medium or Lewfan
speed.
Setthe fan control to Highfor maximum
moisture removal. When the humidity
has been reduced and quiet operation is
preferred, set the fan control to Medium
or Low.
Delay Off
While the dehumidifier is in operation, press
this pad to set it to automatically turn off in 2
hours or 4 hours.
BUCKETFULLLight
Glowswhen the bucket is ready to be emptied, or
when the bucket isremoved or not replaced in the
proper position.
Alarm
Ifthe bucket isfull or missingfor more than 3
minutes,an alarmwill sound for about 10seconds
to remindyou to empty and replacethe bucket.
AutoShutOff
TheWater LevelControl Switch shuts off the
dehumidifier when the bucket isfull, or when
the bucket is removed or not replaced in the
proper position. NOTE: Fanwill continue to run
approximately 3 minutes after bucket is removed.
AutoDefrost
When frost builds up on the evaporator coils,the
compressor will cycle off and the fan will continue
to run until the frost disappears.
Power Outage
Inthe case of a power outage or interruption, the
unit will automatically restart, in the settings last
used,after the power is restored.