58
Service Manual
Installation and Maintenance
9. Troubleshooting
The unit does not 
operate after   
power on 
Fuse  is  burnt  out,  power  cord  is  not 
well plugged, there is no power supplied
for socket or wire inside the  unit is loose. 
Check  if  there  is  power  supplied  for the socket of 
the unit, and then check if  the  plug  and  socket 
contact  well. At  last  check  if  the  wire  inside the 
unit is correct.   
 
The fan motor doesn’t   
operate after power 
on 
Incorrect wiring
Fan capacitor has open circuit or
short circuit. 
Winding  of  motor  has  open  or  short 
circuit, or  temperature limiter is broken 
due  to  overheating. 
 
Replace motor or temperature limiter
Re-wiring
Replace capacitor of fan
Power failure or the fuse is burnt out. 
Check  if  there  is  power  failure,  or  if 
socket is good, or if the plug is loose. 
Repair socket and replace the 
damaged fuse. 
Supply voltage is too low. 
If the voltage of power supply is 10%
lower than the  rated  voltage, find out
the cause.
On-off button has malfunction. 
Press the on-off button. Check if it is in
 
conducting state. If it is not conducted or
not conducted well, replace the button
with the same model
. 
The unit does
 not operate.
Motor of compressor is burnt out. 
If winding of motor of completely
hermetic compressor has short circuit, 
or open circuit, replace the
compressor. 
Compressor has malfunction. 
Knocking the shell of compressor with 
rubber stick may make the 
compressor operate. If it doesn’t work, 
replace the compressor. 
Failure of crystal oscillator or 
reset circuit. 
Replace components with failure.