Section 5 - Specifications
Bend Radius
(Unarmored)
25.4 mm (1.00 in)
Operating
Temperature Range
-55° to 200°C (-67° to 392°F)
4.06 mm (0.0160 in)
5.2.5 Standard Armored Interconnect Cable:
Armored
Materials
Hose Material
Joint Material
Hose Diameter
Outside Diameter
Maximum 0.D
Inside Diameter
Bend Radius
Operating
Temperature Range
Cable
AISI 302 or 304 Stainless Steel
Silver Solder or Welded
Max. 6.99 mm (0.275 in)
Min. 6.68 mm (0.263 in)
Max. 5.16 mm (0.203 in)
Min. 4.65 mm (0.183 in)
38.1 mm (1.50 in)
-34° to 204°C (-29° to 400°F)
See the cable specifications for the standard
interconnect cable.
Splash Resistance Cable/Connector
Cable
Size
Materials
Connector
Insulation
Shield
Jacket
Voltage Rating
1.00 mm2 (18 AWG)
Silver Tinned Copper
Tef lon Jacket
Braided Silver Tinned Copper
Tef lon
600 V