GE DigitalFlow GF868 User Manual

GE DigitalFlow GF868
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
GE
Measurement & Control Gas Analysis
910-194P1 Rev. F
February 2015
DigitalFlow™ GF868
Ultrasonic Flowmeter for Flare Gas
Programming Manual (1-Channel)

Table of Contents

Other manuals for GE DigitalFlow GF868

Question and Answer IconNeed help?

Do you have a question about the GE DigitalFlow GF868 and is the answer not in the manual?

GE DigitalFlow GF868 Specifications

General IconGeneral
TypeUltrasonic Flowmeter
EnclosureNEMA 4X (IP66)
Ingress ProtectionIP66
TechnologyUltrasonic transit-time
Measurement PrincipleTransit-time Ultrasonic
Measurement MethodClamp-on
Pipe Size Range0. 5 inch to 48 inches (12.7 mm to 1220 mm)
Fluid TypesLiquids
Temperature Range-40° to 302°F (-40° to 150°C) (depending on transducer)
Operating Temperature-4° to 140°F (-20° to 60°C)
Power Supply100-240 VAC, 50/60 Hz
Outputs4-20 mA, pulse, relay, frequency
CommunicationRS-232, RS-485, Modbus, HART
Hazardous Area CertificationATEX, IECEx
Accuracy±0.5% to 1% of reading (depending on application)

Summary

Preface

Safety Issues

Covers user responsibilities and hazardous situations related to safety.

Chapter 1. Programming Site Data

1.5 Entering Programming Mode

Details steps to access and navigate the User Program.

1.6 Activating the Channel

Procedure to select the desired measurement method (Skan/Measure).

1.7 Entering System Data

Inputting site label, message, system units, and pressure units.

1.8 Entering Pipe Data

Configuring transducer and pipe parameters like OD, wall thickness.

1.9 Setting Up Inputs/Outputs

Configuring error handling, analog I/O, alarms, and RTD inputs.

1.10 Entering Setup Data

Setting signal limits, response times, and advanced parameters.

1.12 Setting Up Serial Communications

Configuring RS232, MODBUS, Ethernet, and MODBUS/TCP ports.

1.13 Saving Site Data

Storing programmed site data into a non-volatile memory file.

1.15 Activating Security

Setting up password protection to lock specific menus.

Chapter 3. Logging Data

3.2 Creating a Standard Log

Sets up logs, selects parameters, and defines log timing.

3.5 Creating an ERROR Log

Logs generated error messages with parameter values.

Chapter 4. Printing Data

4.2 Print Live Data

Prints live measurement data in numeric or graphical format.

4.3 Printing Logs

Prints logged measurement data from meter memory.

Chapter 5. Clearing Data

Chapter 6. Serial Communications

6.6 Setting Up an Ethernet Connection

Connects the GF868 to a network via Ethernet.

6.7 Setting Up a MODBUS/TCP Connection

Configures MODBUS/TCP communication.

Appendix A. Menu Maps

C.3 Setting Up the Communications Port

Steps to establish communications with the GF868.

C.3.1 Setting up Ethernet Communications

Configures Ethernet communication parameters.

C.5 Editing Meter Properties

Edits GF868 properties such as clock, signals, and files via PanaView.

C.6 Changing Meter Settings

Remotely programs and changes meter operating parameters.

Appendix D. Foundation Fieldbus Communications

Warranty

Certification & Safety Statements

GE Infrastructure Products Used in Hazardous Locations

Provides safety guidelines for equipment used in hazardous locations.

Related product manuals