DigitalFlow™ GF868 Programming Manual (1-Channel) 59
Chapter 4. Printing Data
Chapter 4. Printing Data
4.1 Introduction
The Model GF868 flowmeter has the capability to print any of the data stored in its memory using the built-in RS232
communications port. In order to use the function, the RS232 port must be connected to a printer with a serial port
input. A printer with a parallel port input may be used with a third-party serial-to-parallel adapter.
Note: See Chapter 1, Installation, of the Startup Guide for instructions on wiring the RS232 port. For additional
information, refer to Chapter 6, Serial Communications.
After connecting the Model GF868 to a printer, the Print Menu is used to print live or logged data in either numeric or
graphical format. In addition, any site files stored in memory may be printed. The Print Menu is divided into the
following submenus:
DATA - use to print live data in numeric or graphical format
LOG - use to print a log file in numeric or graphical format
PROG - use to print a site file
STOP - use to terminate any active print jobs
PRNTR - use to specify the printer currently connected
SGNLS - use to print transducer signal array data
RTDs - use to send the numeric point value of a connected RTD device to the RS232 port.
For purposes of this discussion it is assumed that the left pane of the data display screen is active. If the right pane of
the data display screen is active, all of the instructions remain the same, except that any references to the
[F1]-[F4] keys
should be replaced by the [F5]-[F8] keys.
Refer to Figure 15 on page 91, and proceed to the desired section for detailed instructions. As an additional aid, the
relevant portion of the full menu map is reproduced in each section of this chapter. Any submenu may be followed in
the sequence shown or the [and [ keys may be used to scroll through the prompts.
Note: If a printer has not yet been set up, the instructions in “The PRNTR Submenu” must be completed before
proceeding to any of the other submenus.

Table of Contents

Other manuals for GE DigitalFlow GF868

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE DigitalFlow GF868 and is the answer not in the manual?

GE DigitalFlow GF868 Specifications

General IconGeneral
TypeUltrasonic Flowmeter
EnclosureNEMA 4X (IP66)
Ingress ProtectionIP66
TechnologyUltrasonic transit-time
Measurement PrincipleTransit-time Ultrasonic
Measurement MethodClamp-on
Pipe Size Range0. 5 inch to 48 inches (12.7 mm to 1220 mm)
Fluid TypesLiquids
Temperature Range-40° to 302°F (-40° to 150°C) (depending on transducer)
Operating Temperature-4° to 140°F (-20° to 60°C)
Power Supply100-240 VAC, 50/60 Hz
Outputs4-20 mA, pulse, relay, frequency
CommunicationRS-232, RS-485, Modbus, HART
Hazardous Area CertificationATEX, IECEx
Accuracy±0.5% to 1% of reading (depending on application)