5-230 C60 Breaker Protection System GE Multilin
5.7 CONTROL ELEMENTS 5 SETTINGS
5
Figure 5–99: SINGLE-POLE AUTORECLOSE LOGIC (Sheet 2 of 3)
To sheet 3
Lockout
827090AE.CDR
SETTING
Off = 0
Block Bkr1
FLEXLOGIC OPERAND
BREAKER 1 OPEN
AND
OR
AND
TIMER
0
30 ms
OR
FLEXLOGIC OPERAND
BREAKER 1 OOS
PROTECTION & CB
SETTING
No = 0
Transfer 1 to 2
SETTING
Continue = 0
Bkr1 Fail Option
AND
SETTING
= 1
Bkr Sequence
= 2
= 1 & 2
= 1 – 2
= 2 – 1
OR
OR
OR
OR
FLEXLOGIC OPERAND
AR RIP
AR INITIATE
FLEXLOGIC OPERAND
AR LO
from sheet 1
CLOSE
from sheet 1
AND
SETTING
No = 0
Transfer 2 to 1
AND
OR
AND
TIMER
0
30 ms
SETTING
Continue = 0
Bkr2 Fail Option
FLEXLOGIC OPERAND
BREAKER 2 OOS
SETTING
Off = 0
Block Bkr2
FLEXLOGIC OPERAND
BREAKER 2 OPEN
OR
OR
AND
OR
Latch
S
R
Transfer Time
0
SETTING
AND
AND
AND
AND
AND
AND
AND
AND
Lockout
AND
AND
OR
OR
OR
AND
AND
FLEXLOGIC OPERAND
OPEN POLE OP
AND
2 ms
150 ms
OR
AND
FLEXLOGIC OPERAND
BREAKER 1 CLOSED
SETTING
Max Number of Shots
= 4
= 3
= 2
= 1
= 0
= maximum
Increment
shout count
Decrement
shout count
Reset count
OR
AND
FLEXLOGIC OPERANDS
AR SHOT CNT = 4
AR SHOT CNT = 3
AR SHOT CNT = 2
AR SHOT CNT = 1
OR
FLEXLOGIC OPERAND
AR SHOT CNT > 0
SHOT COUNT = MAX
CLOSE BKR 1 OR 2
BKR FAIL TO RECLS
to Lockout
RESET
to autoreclose
logic sheet 1
ACTUAL VALUES
AR SHOT COUNT: 4
AR SHOT COUNT: 3
AR SHOT COUNT: 2
AR SHOT COUNT: 1
AR SHOT COUNT: 0
AND
LOCKOUT
OR
Latch
S
R
FLEXLOGIC OPERAND
AR CLOSE BKR 1
Close Time Bkr1
2 ms
SETTING
AND
BKR1 MNL OPEN
to autoreclose
logic sheet 3
FLEXLOGIC OPERAND
AR BKR 1 BLK
SETTING
Off = 0
Bkr Closed
RESET
from sheet 1
FLEXLOGIC OPERAND
OPEN POLE OP
AND
FLEXLOGIC OPERAND
AR BKR 2 BLK
OR
BKR CLOSED
from sheet 3
AND
OR
Reset Time
0
SETTING
AND
AND
OR
FLEXLOGIC OPERAND
AR RESET
BKR2 MNL OPEN
to autoreclose
logic sheet 3
OR
FLEXLOGIC OPERAND
OPEN POLE OP
AND
Close Time Bkr2
2 ms
SETTING
150 ms
OR
AND
to autoreclose
logic sheet 1
FLEXLOGIC OPERAND
BREAKER 2 CLOSED
AND
LOCKOUT
OR
Latch
S
R
Close Time Bkr2
2 ms
SETTING
FLEXLOGIC OPERAND
AR CLOSE BKR 2
AND
From sheet 1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE C60 and is the answer not in the manual?

GE C60 Specifications

General IconGeneral
BrandGE
ModelC60
CategoryRelays
LanguageEnglish

Related product manuals