GE Multilin C60 Breaker Protection System 2-13
2 PRODUCT DESCRIPTION 2.2 ORDER CODES
2
The order codes for the reduced size vertical mount units with the process bus module are shown below.
| 81 | | | | Eight-port digital process bus module
DIGITAL INPUTS/OUTPUTS XX XX XX None
4A 4A | 4 Solid-State (no monitoring) MOSFET outputs
4B 4B | 4 Solid-State (voltage with optional current) MOSFET outputs
4C 4C | 4 Solid-State (current with optional voltage) MOSFET outputs
4D 4D | 16 digital inputs with Auto-Burnishing (maximum of three modules within a case)
4L 4L | 14 Form-A (no monitoring) Latching outputs
67 67 | 8 Form-A (no monitoring) outputs
6A 6A | 2 Form-A (voltage with optional current) and 2 Form-C outputs, 8 digital inputs
6B 6B | 2 Form-A (voltage with optional current) and 4 Form-C outputs, 4 digital inputs
6C 6C | 8 Form-C outputs
6D 6D | 16 digital inputs
6E 6E | 4 Form-C outputs, 8 digital inputs
6F 6F | 8 Fast Form-C outputs
6G 6G | 4 Form-A (voltage with optional current) outputs, 8 digital inputs
6H 6H | 6 Form-A (voltage with optional current) outputs, 4 digital inputs
6K 6K | 4 Form-C and 4 Fast Form-C outputs
6L 6L | 2 Form-A (current with optional voltage) and 2 Form-C outputs, 8 digital inputs
6M 6M | 2 Form-A (current with optional voltage) and 4 Form-C outputs, 4 digital inputs
6N 6N | 4 Form-A (current with optional voltage) outputs, 8 digital inputs
6P 6P | 6 Form-A (current with optional voltage) outputs, 4 digital inputs
6R 6R | 2 Form-A (no monitoring) and 2 Form-C outputs, 8 digital inputs
6S 6S | 2 Form-A (no monitoring) and 4 Form-C outputs, 4 digital inputs
6T 6T | 4 Form-A (no monitoring) outputs, 8 digital inputs
6U 6U | 6 Form-A (no monitoring) outputs, 4 digital inputs
6V 6V | 2 Form-A outputs, 1 Form-C output, 2 Form-A (no monitoring) latching outputs, 8 digital inputs
INTER-RELAY
COMMUNICATIONS
(select a maximum of 1 per unit)
2A C37.94SM, 1300 nm single-mode, ELED, 1 channel single-mode
2B C37.94SM, 1300 nm single-mode, ELED, 2 channel single-mode
2G IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 1 Channel
2H IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 2 Channels
2I Channel 1 - IEEE C37.94, multimode, 64/128 kbps; Channel 2 - 1300 nm, single-mode, Laser
2J Channel 1 - IEEE C37.94, multimode, 64/128 kbps; Channel 2 - 1300 nm, single-mode, Laser
72 1550 nm, single-mode, Laser 1 Channel
73 1550 nm, single-mode, Laser, 2 Channel
74 Channel 1 - RS422; Channel 2 - 1550 nm, single-mode, Laser
75 Channel 1 - G.703; Channel 2 - 1550 nm, single-mode Laser
76 IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 1 Channel
77 IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 2 Channels
7A 820 nm, multimode, LED, 1 Channel
7B 1300 nm, multimode, LED, 1 Channel
7C 1300 nm, single-mode, ELED, 1 Channel
7D 1300 nm, single-mode, Laser, 1 Channel
7E Channel 1 - G.703; Channel 2 - 820 nm, multimode
7F Channel 1 - G.703; Channel 2 - 1300 nm, multimode
7G Channel 1 - G.703; Channel 2 - 1300 nm, single-mode ELED
7H 820 nm, multimode, LED, 2 Channels
7I 1300 nm, multimode, LED, 2 Channels
7J 1300 nm, single-mode, ELED, 2 Channels
7K 1300 nm, single-mode, LASER, 2 Channels
7L Channel 1 - RS422; Channel 2 - 820 nm, multimode, LED
7M Channel 1 - RS422; Channel 2 - 1300 nm, multimode, LED
7N Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, ELED
7P Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, LASER
7Q Channel 1 - G.703; Channel 2 - 1300 nm, single-mode LASER
7R G.703, 1 Channel
7S G.703, 2 Channels
7T RS422, 1 Channel
7W RS422, 2 Channels
Table 2–7: C60 ORDER CODES (REDUCED SIZE VERTICAL UNITS WITH PROCESS BUS MODULE)
C60 - * ** - * * * - F ** - H ** - M ** - P/R ** Reduced Size Vertical Mount (see note regarding P/R slot below)
BASE UNIT C60 | | | | | | | | | Base Unit
CPU T | | | | | | | | RS485 with 3 100Base-FX Ethernet, multimode, SFP with LC
U | | | | | | | | RS485 with 1 100Base-T Ethernet, SFP RJ-45 + 2 100Base-FX Ethernet, multimode, SFP with LC
V | | | | | | | | RS485 with 3 100Base-T Ethernet, SFP with RJ-45
SOFTWARE 00 | | | | | | | No Software Options
01 | | | | | | | Ethernet Global Data (EGD)
03 | | | | | | | IEC 61850
04 | | | | | | | Ethernet Global Data (EGD) and IEC 61850
14 | | | | | | | Two Phasor Measurement Units (PMUs)
15 | | | | | | | IEC 61850 and two PMUs
A0 | | | | | | | CyberSentry Lvl 1
A1 | | | | | | | CyberSentry Lvl 1 and Ethernet Global Data
A3 | | | | | | | CyberSentry Lvl 1 and IEC 61850
A4 | | | | | | | CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
AE | | | | | | | CyberSentry Lvl 1 and two PMUs
AF | | | | | | | CyberSentry Lvl 1, IEC 61850, and two PMUs
B0 | | | | | | | IEEE 1588
B1 | | | | | | | IEEE 1588 and Ethernet Global Data
B3 | | | | | | | IEEE 1588 and IEC 61850
B4 | | | | | | | IEEE 1588, Ethernet Global Data, and IEC 61850
BE | | | | | | | IEEE 1588 and two PMUs
BF | | | | | | | IEEE 1588, IEC 61850, and two PMUs
C0 | | | | | | | Parallel Redundancy Protocol (PRP)
C1 | | | | | | | PRP and Ethernet Global Data
C3 | | | | | | | PRP and IEC 61850
C4 | | | | | | | PRP, Ethernet Global Data, and IEC 61850
CE | | | | | | | PRP and two PMUs
CF | | | | | | | PRP, IEC 61850, and two PMUs
D0 | | | | | | | IEEE 1588 and CyberSentry Lvl 1
D1 | | | | | | | IEEE 1588, CyberSentry Lvl 1, and Ethernet Global Data
D3 | | | | | | | IEEE 1588, CyberSentry Lvl 1, and IEC 61850
D4 | | | | | | | IEEE 1588, CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
DE | | | | | | | IEEE 1588, CyberSentry Lvl 1, and two PMUs
DF | | | | | | | IEEE 1588, CyberSentry Lvl 1, IEC 61850, and two PMUs
E0 | | | | | | | IEEE 1588 and PRP
E1 | | | | | | | IEEE 1588, PRP, and Ethernet Global Dada
E3 | | | | | | | IEEE 1588, PRP, and IEC 61850
E4 | | | | | | | IEEE 1588, PRP, Ethernet Global Data, and IEC 61850
EE | | | | | | | IEEE 1588, PRP, and two PMUs
EF | | | | | | | IEEE 1588, PRP, IEC 61850, and two PMUs
F0 | | | | | | | PRP and CyberSentry Lvl1
F1 | | | | | | | PRP, CyberSentry Lvl1, and Ethernet Global Data
F3 | | | | | | | PRP, CyberSentry Lvl 1, and IEC 61850
F4 | | | | | | | PRP, CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
FE | | | | | | | PRP, CyberSentry Lvl 1, and two PMUs
FF | | | | | | | PRP, CyberSentry Lvl 1, IEC 61850, and two PMUs
G0 | | | | | | | IEEE 1588, PRP, and CyberSentry Lvl 1
G1 | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, Ethernet Global Data
G3 | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, and IEC 61850
G4 | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
GE | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, and two PMUs
GF | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, IEC 61850, and two PMUs
J0 | | | | | | | IEC 60870-5-103
J1 | | | | | | | IEC 60870-5-103 and EGD
J3 | | | | | | | IEC 60870-5-103 and IEC 61850
J4 | | | | | | | IEC 60870-5-103, EGD, and IEC 61850
JE | | | | | | | IEC 60870-5-103 and two PMUs
JF | | | | | | | IEC 60870-5-103, IEC 61850, and two PMUs
K0 | | | | | | | IEEE 1588, PRP, and IEC 60870-5-103
K1 | | | | | | | IEEE 1588, PRP, IEC 60870-5-103, and EGD
Table 2–6: C60 ORDER CODES (HORIZONTAL UNITS WITH PROCESS BUS MODULE)
C60 - * ** - * * * - F ** - H ** - M ** - P ** - U ** - W/X ** Full Size Horizontal Mount