PRODUCT APPLICATION NOTEVideofied Upgrade - GE Interlogix
SIREN MODE
RIGHT ARROW to SIREN MODE and press YES. Use the arrow keys to
choose the desired siren option followed by YES.
Siren - Input trigger will sound all sirens
Silent - Input trigger will make no noise / feedback
Without Siren - Input trigger will beep keypad only
MAPPING
RIGHT ARROW to MAPPING and press YES. This gives you the option to
capture a video from a MotionViewer when the input is triggered. Use the
arrow keys to choose a installed MotionViewer from the list and press YES
Press and hold the ESC/NO key for 5 seconds to go back to the main screen.
STEP 2: CONFIGURE GE Interlogix OUTPUT
Enter Installer / Programming Mode
Enter
*
8 then installer code
Enter Address of 0 (zero)
* To configure output number 3 (or go to next unprogrammed output option)
Enter Location 49
Enter 24 in segment 1
Enter 2 in Segment 2
> Refer to control panel manual for table of conditions
Press exit button twice to exit