EasyManua.ls Logo

GE JBS03 - Page 38

GE JBS03
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation Instructions
ELECTRICAL CONNECTIONS (CONT.)
r_ 3-WIRE POWER CORD INSTALLATION
Zk
WARNING: Theneutralor ground wire
of the power cord must be connected to the
neutral terminal located in the center of the
terminal block. The power leads must be
connected to the lower left and the lower right
terminals of the terminal block.
[]
Remove the 3 lower terminal screws from the
terminal block. Insert the 3 terminal screws
through each power cord terminal ring and
into the lower terminals of the terminal block.
Be certain that the center wire (white/neutral)
is connected to the center lower position of
the terminal block. Tighten screws securelg
into the terminal block.
DO NOT remove the ground strap
connection,
Terminal
block
J (appearance
may vary)
Ground plate
Neutral
terminal
Ground
strap
Power cord
[] Skip to Step 8 and proceed with the
installation.
rsj 4-WIRE POWER CORD INSTALLATION
[]
[]
[]
[]
WARNING: Theneutralwireofthe
supplg circuit must be connected to the neutral
terminal located in the lower center of the
terminal block. The power leads must be
connected to the lower left and the lower
right terminals of the terminal block. The 4th
grounding lead must be connected to the frame
of the range with the ground plate and the
ground screw.
Remove the 3 lower terminal screws from the
terminal block. Remove the ground screw and
ground plate and retain them.
Cut and discard the ground strap. DO NOT
DISCARDANY SCREWS.
Insert the one ground screw into the power cord
ground wire terminal ring,through the ground
plate and into the frame of the range.
Insertthe 3 terminal screws (removed earlier)
through each power cord terminal ring and into the
lower terminals ofthe terminal block. Becertain that
the center wire (white/neutral) isconnected to the
center lower position of the terminal block. Tighten
screws securelg into the terminal block.
Before .__/__u_tra p
Terminal J_]:_ t_Jl_Q_(J_ _or
,oc,
Ground strap terminal
After Neutral
terminal
Terminal
block
Ground
screw
Ground plate
(grounding
to range)
\
%
[] Skipto Step 8 and proceedwith the installation.