24 MDS TransNEXT Technical Manual MDS 05-7280A01, Rev. A
Dashboard
The “Dashboard” is the default page after login. The screen is organized into 6 sections as shown:
The 3 boxes on the top row, provide the most commonly accessed information.
The About section is for common fixed radio info. It provides Owner Message, Serial#, Network
Address, Firmware and Hardware versions
Network Stats are associated with the ethernet port. They provide running counts of IP traffic,
broken down by TCP, UDP, ICMP(ping), IP payload.
Radio Stats are associated with the operation of the radio itself. This includes RSSI , Output
Power, VSWR status Good/Bad, and link layer counts for Transmission and Reception
The 3 boxes on the bottom row are designed to aid in system troubleshooting:
The Spectrum Analyzer shows the noise floor across the channel. It works by passively sampling
on hops when the TransNEXT is not on the air.
The Payload Viewer provides a running window for displaying the last received OTA payload
data
The RX Signal Analyzer shows the signal strength across the channel of based on receipt of
TransNEXT OTA packets. Note that a master radio will not show any activity until at least one
remote is sync’d and passing data.