www.beutler.com  •   1.800.435.7911  •   M  –   F,  8:00  a . m .  to  5:00 p.m.  • 4700  Lang Avenue  • M c Clellan,  C A   95622
How to arm the system in the Away Mode.
•  Close all sensors (i.e. windows and doors). The Ready indicator should be on.
•  To arm, press Exit key or enter your four or six digit user code to arm the system.
•  The armed icon will turn on.
•  You will have _____ seconds to leave the premises.
How to arm the system in the Stay Mode.2
•  Close all protected doors and windows.
•  Enter your four or six digit user code.
•  Press the Stay key.
How to disarm the system.
•  Enter your user code to disarm the system anytime it is armed.
•  If your code is not valid, the system will not disarm and a two-second error tone will sound. If this happens, try again.
How to reset the smoke detector.
•  Enter *7, this will reset all smoke detectors (your system must be disarmed to use the reset function).
•  If the smoke detectors have gone off, you will need to do this before you can arm the system again.
How to set the date on the keypad.
•  Enter *96 followed by the master code.
•  Enter the Day of Week. 1=Sunday, 2=Monday, 3=Tuesday, 4=Wednesday, 5=Thursday, 6=Friday, and 7=Saturday.
•  Enter the Month Code.  
01 = January  04 = April  07 = July  10 = October 
02 = February  05 = May  08 = August  11 = November 
03 = March  06 = June  09 = September  12 = December
•  Enter the Day Code. Must always be two digits. Example: The 5
th
 would be entered as 05.
•  Enter the last two digits of the Year Code. Example: For 1997 enter 97.--
How to set the system clock.
•  Press *97 followed by the master code.
•  Enter the Hour Code which must be two digits. 
12 a.m. = 00   6 a.m. = 06  12 p.m. = 12  6 p.m. = 18 
1 a.m. = 01    7 a.m. = 07  1 p.m. = 13  7 p.m. = 19 
2 a.m. = 02    8 a.m. = 08  2 p.m. = 14  8 p.m. = 20 
3 a.m. = 03    9 a.m. = 09  3 p.m. = 15  9 p.m. = 21 
4 a.m. = 04    10 a.m. = 10  4 p.m. = 16  10 p.m. = 22 
5 a.m. = 05    11 a.m. = 11  5 p.m. = 17  11 p.m. = 23
•  Enter the Minutes Code which must be two digits. Example: 7 minutes after would be entered 07.
How to bypass one or more zones (To turn off a selected area of the house, while still protecting the rest of the home).
•  Press the Bypass key.
•  Enter the zone you wish to bypass.
•  Press the Bypass key again to confirm.
•  Press the # key to exit the Bypass Mode.
7 8 9
*
0 #
4 5
6
1 2
3
Cancel
Stay
Chim
e
Exi
t
Bypass
Armed
Ready
FIRE
Service
Powe
r
Instant
Master Code ___  ___  ___  ___  ___  ___
Technician Name __________________________________