NX-8 Control
15
Segment 2: 1 = Zone and Box Tamper and Tamper Restore.
2 = Auxiliary Power Overcurrent, Ground Fault, and Restore for both.
3 = Wireless Sensor Missing and Restore.
4 = Wireless Sensor Low Battery and Restore.
5 = Expander Trouble and Restore.
6 = Fail To Communicate.
7 = Reserved.
8 = Reserved.
LOCATION 5 - PARTITIONS REPORTED TO PHONE #1 (1 segment, feature selection data)
Location 5 is used when events to be reported to a phone number are based upon the partition regardless of the
event. If this location is used, location 4 should be programmed as "0".
Segment 1: 1 = Partition #1
2 = Partition #2
3 = Partition #3
4 = Partition #4
5 = Partition #5
6 = Partition #6
7 = Partition #7
8 = Partition #8
L LOCATION 6 - PROGRAMMING PHONE #2 (20 segments, numerical data)
Phone #2 is programmed in location 6. A "14" indicates the end of the phone number. Delays of four seconds can be
programmed at any point in the phone number by programming a "13" in the appropriate segment. If tone dialing is
desired, program a "15" in the segment where tone dialing should begin. If the entire number should be tone dialing,
program a "15" in the first segment. Program an A11" for a Ar@, and a A12" for a A#@.
Caution: A call-waiting cancel on a
non- call waiting line will prevent successful connection to the central station.
L LOCATION 7 - ACCOUNT CODE FOR THE PHONE #2 (6 segments of numerical data)
The account code sent when Phone #2 is dialed is programmed in location 7. Program a A10" in the segment
immediately after the last digit of the account code. If the account code is 6 digits long, program all 6 segments. If
this location is left unprogrammed, account code 1 will be used when the second phone number is dialed.
L LOCATION 8 - COMMUNICATOR FORMAT FOR PHONE # 2 (1 segment, numerical data)
Location 8 contains the communicator format used to transmit to the receiver connected to Phone #2. Consult the
instruction manual for your central station receiver to determine which format is compatible, and select from the 15
formats listed on page 14. If you require a format other than those listed, review the override options described in
Location 18 to build the appropriate format. A "15" must be programmed in location 8 in addition to the entries in
location 18 in order to create a special format. If this location contains a "0", format 1 will be used when Phone #2 is
dialed.
LOCATION 9 - DIAL ATTEMPTS/BACKUP CONTROL FOR PHONE #2 (2 segments, numerical data)
Segment 1, Dial attempts: Segment 1 of Location 9 is used to enter the number of dial attempts (1 to 15 attempts)
the communicator will make to Phone #2 before ending the notification process. Factory default is "8" and the
communicator will make the same number of attempts as those programmed in location 3.
Segment 2, Phone #2 Backup Control: Programming a "0" in Segment 2 of this location will cause the NX-8 to make
the designated number of attempts to Phone #1 before setting the "Fail To Communicate" condition and stop
reporting. Programming a "1" in this segment will cause the NX-8 to stop trying to communicate after the designated
number of attempts have been made to Phone #2. If a "2" is programmed in this segment, it will cause the NX-8 to
make the dial attempts in increments of two. The first two attempts will be made to Phone #2, the next two attempts to
Phone #1, then repeating until the total number of attempts designated in Segment 1 is completed.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NX-1308E - Caddx 8 Zone LED Keypad and is the answer not in the manual?

GE NX-1308E - Caddx 8 Zone LED Keypad Specifications

Power IconPower
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
auxiliary power with NX-320E power supply12 VDC Regulated 2 AMPS
LED keypad current draw130 mA max.
LED keypad zones normal w/o sounder55 mA
NX-148E LCD keypad current draw110 mA max.
NX-148E LCD keypad w/o sounder75 mA
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
Loop Specifications IconLoop Specifications
standard loop resistance300 Ohms Maximum
2-wire smokes resistance30 Ohms Maximum
loop responseSelectable 50mS or 500mS
Weight and Dimensions IconWeight and Dimensions
LED keypad width6.4"
LED keypad height4.0"
LED keypad depth1.1"
NX-148E LCD keypad width6.4"
NX-148E LCD keypad height5.3"
NX-148E LCD keypad depth1.0"
metal enclosure width11.25"
metal enclosure height11.25"
metal enclosure depth3.50"
shipping weight9 lbs.