NX-8 Control
31
LOCATION 74 - EXPANDER TROUBLE AND EXPANDER TROUBLE RESTORE COMMUNICATOR CODES,
SLOW SPEED FORMATS ONLY (4 segments, numerical data)
Location 74 contains the tens and ones digits for a 4+2 format that will be sent if "Expander Trouble Reporting" is
enabled. Segment 1 contains the tens digit of the "Expander Trouble Reporting". Segment 2 contains the ones digit
of the "Expander Trouble Reporting". Segment 3 contains the tens digit of the "Expander Trouble Restore". Segment
4 contains the ones digit of the "Expander Trouble Restore".
LOCATION 75 - FAIL TO COMMUNICATE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY
(2 segments, numerical data)
Location 75 contains the tens and ones digits for a 4+2 format that will be sent if the "Fail To Communicate
Reporting" is enabled. Segment 1 contains the tens digit, segment 2 contains the ones digit.
LOCATION 76 - LOG FULL COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (2 segments, numerical
data)
Location 76 contains the tens and ones digits for a 4+2 format if the "Log Full Reporting" is enabled. Segment 1
contains the tens digit, segment 2 contains the ones digit.
LOCATION 77 - OPENING COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments, numerical
data)
Location 77 contains the tens digit of a 4+2 format if the "Opening Reporting" is enabled. The ones digit is the ones
digit of the user number that did the opening. If the user is greater than 9, the numbers will begin repeating. If
it is required to report openings and closings for more than 9 users, Contact ID or SIA format must be used. Any
segment left as "0" will follow the Segment 1 selection.
Segment 1 - Opening Code for Partition #1.
Segment 2 - Opening Code for Partition #2.
Segment 3 - Opening Code for Partition #3.
Segment 4 - Opening Code for Partition #4.
Segment 5 - Opening Code for Partition #5.
Segment 6 - Opening Code for Partition #6.
Segment 7 - Opening Code for Partition #7.
Segment 8 - Opening Code for Partition #8.
LOCATION 78 - CLOSING COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments, numerical
data)
Location 78 contains the tens digit of a 4+2 format if the "Closing Reporting" is enabled. The ones digit is the ones
digit of the user number that did the closing. If the user is greater than 9, the numbers will begin repeating. If
it is required to report openings and closings for more than 9 users, Contact ID or SIA format must be used. Any
segment left as "0" will follow the Segment 1 selection.
Segment 1 - Closing Code for Partition #1.
Segment 2 - Closing Code for Partition #2.
Segment 3 - Closing Code for Partition #3.
Segment 4 - Closing Code for Partition #4.
Segment 5 - Closing Code for Partition #5.
Segment 6 - Closing Code for Partition #6.
Segment 7 - Closing Code for Partition #7.
Segment 8 - Closing Code for Partition #8.
LOCATION 79 - AUTOTEST COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (2 segments, numerical
data)
Location 79 contains the tens and ones digits for a 4+2 format that will be sent if the "Autotest" or "Manual Test" is
enabled. Segment 1 contains the tens digit segment 2 contains the ones digit.
LOCATION 80 - RECENT CLOSING AND EXIT ERROR COMMUNICATOR CODE, SLOW SPEED FORMATS
ONLY (2 segments, numerical data)
Location 80 contains the tens digit for a 4+2 format that will be sent if "Recent Closing" and/or "Exit Error Reporting" is
enabled. Segment 1 contains the tens digit for the "Recent Closing Reporting". Segment 2 contains the digit for the
"Exit Error Reporting". The ones digit is the ones digit of the user who closed. If the user number is greater
than 9, the numbers will begin repeating (i.e. 9 for user 29). If it is required to report Recent Closings and Exit
Errors for more than 9 users, Contact ID or SIA format must be used.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NX-1308E - Caddx 8 Zone LED Keypad and is the answer not in the manual?

GE NX-1308E - Caddx 8 Zone LED Keypad Specifications

Power IconPower
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
auxiliary power with NX-320E power supply12 VDC Regulated 2 AMPS
LED keypad current draw130 mA max.
LED keypad zones normal w/o sounder55 mA
NX-148E LCD keypad current draw110 mA max.
NX-148E LCD keypad w/o sounder75 mA
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
Loop Specifications IconLoop Specifications
standard loop resistance300 Ohms Maximum
2-wire smokes resistance30 Ohms Maximum
loop responseSelectable 50mS or 500mS
Weight and Dimensions IconWeight and Dimensions
LED keypad width6.4"
LED keypad height4.0"
LED keypad depth1.1"
NX-148E LCD keypad width6.4"
NX-148E LCD keypad height5.3"
NX-148E LCD keypad depth1.0"
metal enclosure width11.25"
metal enclosure height11.25"
metal enclosure depth3.50"
shipping weight9 lbs.

Related product manuals