Inverter Compressor (cont.)
Compressor operation is extremely smooth and cool. The temperature of the
compressor exterior may be slightly higher than room temperature while
operating; therefore, it may be difficult to detect a running unit.
To verify that the compressor is running:
Disconnect power from the unit and place a hand on the compressor. Reconnect
power and feel for a vibration when the compressor tries to start. It may take up
to 8 seconds before the compressor attempts to start.
Note:
When ordering a replacement compressor, order both the compressor and
inverter. Replace the compressor first. If it fails to start, replace the
inverter.
When servicing the compressor, it is important to dress the wiring to keep
low voltage DC wiring and 120 VAC wiring separate.