– 36 –
Dispenser and Interface
The dispenser assembly incorporates the interface
used for temperature control and features. The
interface has 2 tabs that hold it to the dispenser
housing. The tabs are located above 2 slots located
behind the bottom of the interface.
To remove the water dispenser assembly:
1. Using a at blade screwdriver, pry the bottom of
the interface away from the dispenser recess.
Slot
Slot
10. Remove the four T-10 Torx screws that attach
the auger motor to the housing.
11. Remove the 1/2-in. hex-head nut, auger fork,
and the metal front cover from the auger motor.
Front Cover
Auger Fork
Check for auger motor supply voltage of 120 VAC on
the disconnected auger motor wire harness.
Crushed rotation - orange (neutral) to beige wire
Cubed rotation - orange (neutral) to silver wire
Note: To center the ice bucket cam and unload the
crusher, the auger motor does a quick “reverse”
action when dispensing is stopped (glass removed).
(Not noticeable to consumer)
Neutral CrushedCubed
(Continued next page)