EasyManua.ls Logo

GEA Grasso 5 - Restart after a Long Standstill Period of Time; Stopping the Compressor

GEA Grasso 5
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Refer to Section 1.4.10.2, Page 31.
1.4.10.4 Restart after a long standstill period of time
After a seasonal standstill (1 to 6 months) or maintenance operations;
Warning!
After a standstill period of time more than 1 month, pre-lubrication just
before starting is always obligatory. Refer Section 4.7, Page 61
Check settings of control and safety equipment.
Proceed to the complete starting procedure.
Warning!
Restarting compressor after a standstill period of time more than 6
months, consult your supplier. It is recommended to proceed with the
initial start up procedure.
1.4.10.5 Stopping the compressor
The compressor can be stopped at any moment, however, consult the supplier if
further actions are required.