User Guide Electrical Line Shaft for ADV200 Page 8 of 72
The source of the encoder used for Flux vector CL control cannot be the same used for the Master
encoder. The selection must be static (IPA 5310 Encoder sel src = Null or One).
Configure the drive so that its absolute maximum speed is higher than that of its master to ensure
sufficient operating margin during following, engage transients, or phase corrections. In addition,
speed range with respect to set ratios must obviously be taken into account.
There are no limitations on the use of encoder expansion cards other than those deriving from
combinations allowed by the expansion slots compared to other types of cards (Fieldbus, Fast Link,
IO, etc). For details, see the “ADV200QS Quick installation guide” manual
There are no limitations on the use of fieldbus expansion cards other than those deriving from
combinations allowed by the expansion slots compared to other types of cards (Encoder, Fast Link,
IO, etc). For details, see the “ADV200QS Quick installation guide” manual
There are no limitations on the use of the Fast Link expansion card other than those deriving from
combinations allowed by the expansion slots compared to other types of cards (Encoder, Fieldbus,
IO, etc). For details, see the “ADV200QS Quick installation guide” manual
There are no limitations on the use of I/O expansion cards other than those deriving from combinations
allowed by the expansion slots compared to other types of cards (Encoder, Fieldbus, Fast Link, etc).
For details, see the “ADV200QS Quick installation guide” manual
You cannot assign more than one application function to the same digital input (and/or decomp
bit);
You cannot use Dimension Factor system functions.