    How to fix overvoltage on gefran ADV200 SP DC Drives?
    • G
      George JohnsonAug 15, 2025
      An overvoltage in Gefran DC Drives typically occurs due to energy recovered from the motor, causing the voltage arriving at the drive power section to exceed the maximum threshold set by the PAR 560 Mains voltage parameter. To resolve this, you can try extending the deceleration ramp, using a braking resistor between terminals BR1 and BR2 to dissipate the recovered energy, or utilizing the Vdc Control function.
  • S
    sarahdavisAug 18, 2025
    What to do if I get an overcurrent alarm on my gefran ADV200 SP?
    • J
      Jennifer WallAug 19, 2025
      An overcurrent in Gefran DC Drives is often due to the incorrect setting of current regulator parameters or a short circuit between phases or ground fault on the drive output. To address this, check the current regulator parameters and inspect the wiring towards the motor.
  • H
    harttonyAug 21, 2025
    Why is my Gefran DC Drives showing an undervoltage error?
    • S
      sheryl20Aug 22, 2025
      Undervoltage in Gefran DC Drives happens when the voltage arriving at the drive power section is too low compared to the minimum threshold relating to the 560 Mains voltage parameter setting because of: the mains voltage being too low or overextended voltage drops; or poor cable connections. Check the related connections of the drive power supply and its correct range.
  • J
    John NunezAug 25, 2025
    What causes a heatsink OT (over temperature) alarm on gefran ADV200 SP DC Drives?
    • A
      Amanda RosalesAug 26, 2025
      A heatsink temperature too high alarm in Gefran DC Drives indicates that the heatsink temperature is too high. Verify the correct operation of the cooling fan, check that the heatsinks are not clogged, and ensure that the openings for the cabinet cooling air are not blocked.
  • A
    Ashley DixonAug 28, 2025
    How to troubleshoot a ground fault on Gefran DC Drives?
    • A
      Ashley BrownAug 28, 2025
      A ground fault in Gefran DC Drives indicates a ground short circuit alarm. Check the drive and motor wiring, and verify that the motor is not grounded.
  • J
    John WilliamsSep 1, 2025
    What does MultiOvercurr mean on Gefran DC Drives?
    • M
      Miranda EvansSep 1, 2025
      MultiOvercurr in Gefran DC Drives means there were too many Overcurrent alarms. Adopt the proposed solutions for the Overcurrent alarm.
  • E
    ericspearsSep 4, 2025
    What does MultiUndervolt mean on gefran ADV200 SP?
    • B
      bkempSep 4, 2025
      MultiUndervolt on Gefran DC Drives indicates too many Undervoltage alarms. Adopt the proposed solutions for the Undervoltage alarm.
  • D
    dawn82Sep 7, 2025
    What does MultiDesat mean on Gefran DC Drives?
    • M
      Michele GreerSep 7, 2025
      MultiDesat in Gefran DC Drives means there were too many Desaturation alarms. Adopt the proposed solutions for the Desaturation alarm.
  • L
    Lisa AdamsSep 12, 2025
    What to do if gefran ADV200 SP DC Drives show desaturation alarm?
    • P
      Peter NicholsonSep 12, 2025
      For a desaturation alarm on Gefran DC Drives, switch the drive off and then switch it on again. If the alarm persists, contact the technical service centre.

gefran ADV200 SP Series Specifications

General IconGeneral
CategoryDC Drives
Supply Voltage110...690 VAC ±10%
Input Voltage110...690 VAC ±10%
Output Current Range5...2250 A
Output Current5...2250 A
Power Range1.5...1250 kW
Enclosure RatingIP00, IP20
Operating Temperature0...+45 °C (32...113 °F)
Storage Temperature-25...+70 °C (-13...158 °F)

Related product manuals